User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 System Wiring
- Chapter 3 Installation
- Chapter 4 General Wiring
- 4.1 Components Introduction
- 4.2 Wiring
- 4.3 Terminal Description
- 4.3.1 Main Lane Control Board Terminal Description
- 4.3.2 Sub Lane Control Board Terminal Description
- 4.3.3 Access Control Board Terminal Description
- 4.3.4 Sub Optional Board Terminal Description (Optional)
- 4.3.5 Card Reader Board Terminal Description
- 4.3.6 Main Optional Board Terminal Description (Optional)
- 4.3.7 General Wiring
- 4.3.8 RS-485 Wiring
- 4.3.9 RS-232 Wiring
- 4.3.10 Alarm Input Wiring
- 4.3.11 Exit Button Wiring
- 4.4 Device Settings
- Chapter 5 Activation
- Chapter 6 Operation via Web Browser
- 6.1 Login
- 6.2 Live View
- 6.3 Person Management
- 6.4 Search Event
- 6.5 Configuration
- 6.5.1 View Device Information
- 6.5.2 Set Time
- 6.5.3 Set DST
- 6.5.4 Change Administrator's Password
- 6.5.5 Online Users
- 6.5.6 View Device Arming/Disarming Information
- 6.5.7 Network Settings
- 6.5.8 Event Linkage
- 6.5.9 Access Control Settings
- 6.5.10 Turnstile
- 6.5.11 Card Settings
- 6.5.12 Set Privacy Parameters
- 6.5.13 Upgrade and Maintenance
- 6.5.14 Device Debugging
- 6.5.15 Component Status
- 6.5.16 Log Query
- 6.5.17 Certificate Management
- Chapter 7 Client Software Configuration
- 7.1 Configuration Flow of Client Software
- 7.2 Device Management
- 7.3 Group Management
- 7.4 Person Management
- 7.5 Configure Schedule and Template
- 7.6 Set Access Group to Assign Access Authorization to Persons
- 7.7 Configure Advanced Functions
- 7.8 Door/Elevator Control
- Appendix A. DIP Switch
- Appendix B. Button Configuration Description
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
- Appendix E. Error Code Description
- Appendix F. Communication Matrix and Device Command
Door Locked Time
Aer swiping the normal card and relay acon, the mer for locking the door starts working.
Extended Open Duraon
The door contact can be enabled with appropriate delay aer person with extended accesss
needs swipes her/his card.
Door Le Open Timeout Alarm
The alarm can be triggered if the door has not been closed in a congured me period. If it is
set as 0, no alarm will be triggered.
Lock Door when Door Closed
The door can be locked once it is closed even if the Door Locked Time is not reached.
Duress Code
The door can open by inpung the duress code when there is duress. At the same me, the
client can report the duress event.
Super Password
The specic person can open the door by inpung the super password.
Dismiss Code
Create a dismiss code which can be used to stop the buzzer of the card reader (by entering
the dismiss code on the keypad).
Note
●
The duress c
ode, super code, and dismiss code should be dierent.
●
The duress code, super password, and the dismiss code should be dierent from the
authencaon password.
●
The length of duress code, super password, and the dismiss code is according the device,
usually it should contains 4 to 8 digits.
5.
Click OK.
6.
Oponal: Click Copy to , and then select the
door/oor(s) to copy the parameters in the page to
the selected doors/oor(s).
Note
The door or oor's status duraon sengs will be c
opied to the selected door/oor(s) as well.
Congure Parameters for Card Reader
Aer adding the access control device, you can congure its card reader parameters.
Bef
ore You Start
Add access control device to the client.