User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 System Wiring
- Chapter 3 Installation
- Chapter 4 General Wiring
- 4.1 Components Introduction
- 4.2 Wiring
- 4.3 Terminal Description
- 4.3.1 Main Lane Control Board Terminal Description
- 4.3.2 Sub Lane Control Board Terminal Description
- 4.3.3 Access Control Board Terminal Description
- 4.3.4 Sub Optional Board Terminal Description (Optional)
- 4.3.5 Card Reader Board Terminal Description
- 4.3.6 Main Optional Board Terminal Description (Optional)
- 4.3.7 General Wiring
- 4.3.8 RS-485 Wiring
- 4.3.9 RS-232 Wiring
- 4.3.10 Alarm Input Wiring
- 4.3.11 Exit Button Wiring
- 4.4 Device Settings
- Chapter 5 Activation
- Chapter 6 Operation via Web Browser
- 6.1 Login
- 6.2 Live View
- 6.3 Person Management
- 6.4 Search Event
- 6.5 Configuration
- 6.5.1 View Device Information
- 6.5.2 Set Time
- 6.5.3 Set DST
- 6.5.4 Change Administrator's Password
- 6.5.5 Online Users
- 6.5.6 View Device Arming/Disarming Information
- 6.5.7 Network Settings
- 6.5.8 Event Linkage
- 6.5.9 Access Control Settings
- 6.5.10 Turnstile
- 6.5.11 Card Settings
- 6.5.12 Set Privacy Parameters
- 6.5.13 Upgrade and Maintenance
- 6.5.14 Device Debugging
- 6.5.15 Component Status
- 6.5.16 Log Query
- 6.5.17 Certificate Management
- Chapter 7 Client Software Configuration
- 7.1 Configuration Flow of Client Software
- 7.2 Device Management
- 7.3 Group Management
- 7.4 Person Management
- 7.5 Configure Schedule and Template
- 7.6 Set Access Group to Assign Access Authorization to Persons
- 7.7 Configure Advanced Functions
- 7.8 Door/Elevator Control
- Appendix A. DIP Switch
- Appendix B. Button Configuration Description
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
- Appendix E. Error Code Description
- Appendix F. Communication Matrix and Device Command
Steps
1.
Click Access Control → Advanced Funcon → Device Parameter .
2.
In the device list on the le, click to expand the door, select a card reader and you can edit the
card reader's parameters on the right.
3.
Edit the card reader basic parameters in the Basic Informaon page.
Note
●
The displa
yed parameters may vary for dierent access control devices. There are part of
parameters listed as follows. Refer to the user manual of the device for more details.
●
Some of the following parameters are not listed in the Basic Informaon page, click More to
edit the parameters.
Name
E
dit the card reader name as desired.
OK LED Polarity/Error LED Polarity/Buzzer Polarity
Set OK LED Polarity/Error LED Polarity/Buzzer LED Polarity of main board according to the
card reader parameters. Generally, adopts the default sengs.
Minimum Card Swiping Interval
If the interval between card swiping of the same card is less than the set value, the card
swiping is invalid. You can set it as 0 to 255.
Max. Interval When Entering PWD
When you inpung the password on the card reader, if the interval between pressing two
digits is lar
ger than the set value, the digits you pressed before will be cleared automacally.
Alarm of Max. Failed Aempts
Enable to report alarm when the card reading aempts reach the set value.
Ma
x. Times of Card Failure
Set the max. failure aempts of reading card.
T
ampering Detecon
Enable the an-tamper detecon for the card reader.
Communicate with Controller Every
When the access control device cannot connect with the card reader for longer than the set
me, the card reader will turn oine
automacally.
Buzzing Time
Set the card reader buzzing me. The available me ranges from 0 to 5,999s. 0 represents
connuous buzzing.
Card Reader Type/Card Reader Descripon
Get card reader type and descripon. They are read-only.
Fingerprint Recognion Level