7
2.2 Installing Device
Before you start:
Prepare for the installation tools, check the device and the accessories, and clear the installation
base.
Notes:
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
In general, because of the limitation of installation and maintenance, the suggested distance
between the wall and the pedestal is more than 50 mm.
Steps:
1. Draw a line on central installation surface of the left or right pedestal.
2. Draw another two parallel lines for installing the other two pedestals.
Note: The distance between the nearest two line is L+100 mm. L represents the lane width.
3. Drill holes on the ground according to the installation holes on the pedestals and insert the
expansion sleeves.
4. Bury interconnecting cables for pedestal communication.
Note: For detailed information about burying and wiring interconnecting cables, see 4.3 Wiring
Interconnecting Cable.
5. According to the entrance and exit marks on the pedestals, move the pedestals to the
corresponded positions.
Note: Make sure the installation holes on the pedestals and the base are aligned with each
other.
6. Secure the pedestals with expansion bolts.
The installation footprint is as follows: