User's Manual
Table Of Contents
- Chapter 1 Overview
- Chapter 2 Installation
- Chapter 3 Disassembling before Maintenance
- Chapter 4 Wiring
- 4.1 Components Introduction
- 4.2 Wiring Electric Supply
- 4.3 Wiring Interconnecting Cable
- 4.4 Terminal Description
- 4.4.3 Master Control Board Terminal Description
- 4.4.4 Slave Control Board Terminal Description
- 4.4.5 Main Control Board Terminal Description
- 4.4.6 Main Control Board Serial Port ID Description
- 4.4.7 RS-485 Wiring
- 4.4.8 RS-232 Wiring
- 4.4.9 Wiegand Wiring
- 4.4.10 Barrier Control Wiring
- 4.4.11 Alarm Output Wiring
- 4.5 Wiring Lithium Battery (Optional)
- Chapter 5 Device Settings
- Chapter 6 Device Activation
- Chapter 7 Client Operation
- 7.1 Function Module
- 7.2 Access Control Management
- 7.2.1 Adding Access Control Device
- 7.2.2 Viewing Device Status
- 7.2.3 Editing Basic Information
- 7.2.4 RS-485 Settings
- 7.2.5 Authenticating M1 Card Encryption
- 7.2.6 Remote Configuration
- Checking Device Information
- Editing Device Name
- Editing Time
- Setting System Maintenance
- Setting RS-485 Parameters
- Managing Network User
- Managing Remote Control User
- Setting Security
- Configuring Passing Parameters
- Configuring Screen Parameters
- Configuring People Counting Parameters
- Configuring Network Parameters
- Configuring Advanced Network
- Configuring Relay Parameters
- Configuring Audio File
- Operating Relay
- Viewing Relay Status
- 7.3 Organization Management
- 7.4 Person Management
- 7.5 Permission Configuration
- 7.6 Advanced Functions
- 7.7 Searching Access Control Event
- 7.8 Access Control Event Configuration
- 7.9 Door Status Management
- 7.10 Arming Control
- 7.11 Time and Attendance
- Appendix A Tips for Scanning Fingerprint
- Appendix B DIP Switch Description
- Appendix C Table of Audio Index Related Content
Swing BarrierยทUser Manual
26
UART1 Jumper Cap:
Use the jumper cap to switch the serial port communication
mode with the master lane controller. You can switch
between the RS-484 communication mode and the RS-232
communication mode. By default, it is in RS-485
communication mode.
Lane:
Use the jumper cap to switch the serial port communication
mode with the lane controller. By default, the interface is
wired and it is in RS-485 communication mode.
If wiring other controllers (compatible with Hikvision
communication protocol), use the jumper cap to switch
between RS-485 and RS-232 communication mode.
UART4:
The serial port is in the wiring interface according to the
picture above, which has a fixed RS-232 communication
mode to communicate with the master lane controller. It
contains no jumper cap and cannot change the
communication mode.
UART7/UART8:
Reserved serial port. The serial port has a fixed RS-232
communication mode. It contains no jumper cap and cannot
change the communication mode. It can connect QR code
scanner, card recycler, and text screen.
The reserved interface positions in the swing barrier and their corresponded UART No. are as
follows: