DS-K3Y411X Series Flap Barrier Quick Start Guide
DS-K3Y411X Series Flap Barrier Quick Start Guide Legal Information ©2021 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved. About this Manual The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change, without notice, due to firmware updates or other reasons.
DS-K3Y411X Series Flap Barrier Quick Start Guide DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES. IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS. Data Protection During the use of device, personal data will be collected, stored and processed.
DS-K3Y411X Series Flap Barrier Quick Start Guide Regulatory Information FCC Information Please take attention that changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
DS-K3Y411X Series Flap Barrier Quick Start Guide under the EMC Directive 2014/30/EU, RE Directive 2014/53/EU,the RoHS Directive 2011/65/EU 2012/19/EU (WEEE directive): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. For more information see: www.recyclethis.
DS-K3Y411X Series Flap Barrier Quick Start Guide Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into Dangers and Cautions: Dangers: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage. Dangers: Follow these safeguards to prevent serious injury or death.
DS-K3Y411X Series Flap Barrier Quick Start Guide ● ● Do not ingest battery, Chemical Burn Hazard. This product contains a coin/button cell battery. If the coin/button cell battery is swallowed, it can cause severe internal burns in just 2 hours and can lead to death. Keep new and used batteries away from children. If the battery compartment does not close securely, stop using the product and keep it away from children.
DS-K3Y411X Series Flap Barrier Quick Start Guide ● ● ● ● ● ● ● Please keep all wrappers after unpack them for future use. In case of any failure occurred, you need to return the device to the factory with the original wrapper. Transportation without the original wrapper may result in damage on the device and lead to additional costs. Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or equivalent type only.
DS-K3Y411X Series Flap Barrier Quick Start Guide Available Models Product Name Flap Barrier Model Description Example DS-K3Y411X-L1 Left Pedestal 1 DS-K3Y411X-L1/Dp60 DS-K3Y411X-L1/Dp60S12 DS-K3Y411X-L2 Left Pedestal 2 DS-K3Y411X-L2/Dp60 DS-K3Y411X-L2/Dp60S12 DS-K3Y411X-M1 Middle Pedestal 1 DS-K3Y411X-M1/MDp60 DS-K3Y411X-M1/MDp60-S12 DS-K3Y411X-M2 Middle Pedestal 2 DS-K3Y411X-M2/MDp60 DS-K3Y411X-M2/MDp60-S12 DS-K3Y411X-R Right Pedestal DS-K3Y411X-R/M-Dp60 DS-K3Y411X-R/MDp60-S12 You can f
DS-K3Y411X Series Flap Barrier Quick Start Guide Scan the QR code to get User Manual of Flap Barrier. Note that mobile data charges may apply if Wi-Fi is unavailable.
DS-K3Y411X Series Flap Barrier Quick Start Guide Contents Chapter 1 Overview .................................................................................................................... 1 1.1 Introduction ........................................................................................................................... 1 1.2 Main Features ........................................................................................................................ 1 Chapter 2 System Wiring .......
DS-K3Y411X Series Flap Barrier Quick Start Guide 5.3 Switch Relay Output Mode (NO/NC) .................................................................................... 43 5.3.1 Barrier Control Relay Output Mode ............................................................................ 43 5.3.2 Alarm Relay Output Mode (NO/NC) ............................................................................ 44 Chapter 6 Activation ...............................................................................
DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 1 Overview 1.1 Introduction The flap barrier with two barriers and 12 IR lights is designed to detect unauthorized entrance or exit. By adopting the flap barrier integratedly with the access control system, person should authenticate to pass through the lane via swiping IC or ID card, scanning QR code, etc. It is widely used in attractions, stadiums, construction sites, residences, etc. 1.
DS-K3Y411X Series Flap Barrier Quick Start Guide ● ● ● ● ● ● ● Remote control and management Online/offline operation LED indicates the entrance/exit and passing status Barrier is in open status when powered down; If the device is installed with supercapacitor, the barrier remains open when powered down Fire alarm passing When the fire alarm is triggered, the barrier will be open automatically for emergency evacuation Valid passing duration settings System will cancel the passing permission if a person
DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 2 System Wiring The preparation before installation and general wiring. Steps 1. Draw a central line on the installation surface of the left or right pedestal. 2. Draw other parallel lines for installing the other pedestals. Note The distance between the nearest two line is L+200 mm. L represents the lane width. 3. Slot on the installation surface and dig installation holes according to the hole position diagram. Figure 2-1 Hole Position Diagram 4.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 2-2 System Wiring Diagram (General Wiring) ● ● ● ● ● ● Note The supplied interconnecting cable length is 3.75 m. If you need a longer one, you can buy a new accessory. The suggested inner diameter of the low voltage conduit is larger than 30 mm. If you want to bury both of the AC power cord and the low voltage cable at the entrance, the two cables should be in separated conduits to avoid interference.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 2-3 Wire Face Recognition Terminal ● ● ● ● ● ● ● Note The face recognition terminal installed on the left pedestal will gain power from the sub switch, which should connect to high voltage. The suggested inner diameter of the low voltage conduit is larger than 30 mm. The supplied interconnecting cable length is 3.75 m. If you need a longer one, you can extend the cable by yourself.
DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 3 Installation 3.1 Disassemble Pedestals Before installation, you should use the key to open the pedestals. View the pictures below to find the lock holes.
DS-K3Y411X Series Flap Barrier Quick Start Guide Note Please check and avoid metal pieces dropped into the high and low voltage modules, which will cause short circuit. 3.2 Install Pedestals Before You Start Prepare for the installation tools, check the device and the accessories, and clear the installation base. Steps ● ● ● Note The device should be installed on the concrete surface or other non-flammable surfaces.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 3-2 Dimension 1. Prepare for the installation tools, check the components, and prepare for the installation base. 2. Drill holes on the ground according to the installation holes on the pedestals and insert the expansion sleeves. According to the entrance and exit marks on the pedestals, move the pedestals to the 3. corresponded positions. Note Make sure the installation holes on the pedestals and the base are aligned with each other. 4.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 3-3 Installation Footprint 5. After installation, assemble the components and screws back to the pedestal in reverse order (except for protective sheets).
DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 4 General Wiring ● ● Note After maintenance, you should close the water-proof cover over the high/low voltage module. When you should maintain or disassemble the high voltage modules, you should remove the entire high voltage modules and maintain it outside the turnstile. You should unplug the cables that connected to the peripherals before maintenance to avoid destroy of the device. 4.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-1 Components Diagram 1 Note The reinstalled supercapacitor needs to be powered on for at least 3 minutes before it can work normally. The picture displayed below describes the IR adapter and the IR sending/receiving board and their corresponding number on the pedestal.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-2 Components 2 Note If the turnstile contains two lanes, standing at the entrance position, the IR boards on the left pedestal are the IR sending boards. The IR boards on the right pedestal are the IR receiving boards. The IR boards on the left side of the middle pedestal are the IR receiving boards, while the IR boards on the right side of the middle pedestal are the IR sending boards. 4.
DS-K3Y411X Series Flap Barrier Quick Start Guide ● ● ● ● Note The cable bare part should be no more than 8 mm. It is suggested that you can immerse the bare part into the liquid tin. If possible, wear an insulation cap at the end of the bare cable. Make sure there’s no bare copper or cable after the wiring. The Terminal L and the Terminal N cannot be wired reversely. Do not wire the input and output terminal reversely.
DS-K3Y411X Series Flap Barrier Quick Start Guide 4.3 Wire Interconnecting Cable You should use interconnecting cables to connect the main lane board and the sub lane board for components communication. Note The right/middle pedestal contains an interconnecting cable, including one network cable (5.5 m) and one 2-core cable. The picture displayed below describes the cable hole's position on the pedestals.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-4 Wiring Method of Slotting in Middle Follow the instructions below to connect the interconnecting cable.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-5 Connect Interconnecting Cable 4.4 Face Recognition Terminal Power Supply Wiring (Optional) If connect to face recognition terminals, the face recognition terminals of right pedestal and middle pedestal (entrance) will power supplied by 12 V terminal on left side of the pedestal. The face recognition terminal of left pedestal and middle pedestal (exit) will power supplied by 12 V terminal of the power adaptor of the right pedestal.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-6 Face Recognition Terminal Power Supply Wiring 4.5 Terminal Description The lane controller contains main lane controller and sub lane controller, which controls the IR beams, motor, and other components' work. 4.5.1 UART Related Terminal and Position View the UART position on the lane control board and the access control board. You can also view the UART related terminals and DIP switch information.
DS-K3Y411X Series Flap Barrier Quick Start Guide Note The diagram is for reference only. Figure 4-7 Interface and Corresponded UART No. The UART related terminals are on the access control board and BUS of the lane control board. You can switch between the RS-232 and the RS-485 communication modes via DIP switch.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-8 UART No. Description Table 4-1 UART Related Position/Terminals/DIP Switch Introduction UART No. UART1 Related Terminals Terminal Position 485A/232A Note External card reader is recommended to access. UART3 485C+/232C+ DIP Switch No.
DS-K3Y411X Series Flap Barrier Quick Start Guide UART No. Related Terminals Terminal Position Note External card reader is recommended to access. 485C-/232C- UART5 485E+/232E+ Note External card reader is recommended to access. UART6 Note Face recognition terminal is recommended to access. BUS of Sub Lane Control Board 485E-/232E485F+/232F+ BUS of Sub Lane Control Board 485F-/232F- DIP Switch No.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-9 Main Control Board Terminal 4.5.3 Sub Control Board Terminal Description The sub lane control board contains power input, BUS interface, interconnecting interface, supercapacitor interface, barrier position control board interface and motor drive interface. The picture displayed below is the sub control board diagram.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-10 Sub Control Board Terminal 4.5.4 BUS Terminal Description You can connect the lane controller light board, fan, TAMPER, lane control board, card reader, face recognition terminal, QR code scanner, etc. via the BUS terminal. Note Part of the wiring has been completed at the factory, please connect according to actual needs.
DS-K3Y411X Series Flap Barrier Quick Start Guide Terminal Name Description UART 1 Red 12 V: connects 12 VDC power supply terminal Note External card reader is recommended to access.
DS-K3Y411X Series Flap Barrier Quick Start Guide Table 4-4 BUS Terminal in Sub Lane Controller (Middle Pedestal) Terminal Name Description Lane Controller Light Board 1 Connects lane controller light board 1 Lane Controller Light Board 2 Connects lane controller light board 2 Lane Controller Board Connect sub lane controller board 5V Reserved IR Adaptor Connects IR adaptor UART 5 Red 12 V: connects 12 VDC power supply terminal Note External card reader is recommended to access.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-11 Access Control Board Terminal Table 4-5 Access Control Board Terminal Description Access Control Board Terminal Description Power Output 1 RS-485 Interface +12 V 12 VDC Power Output G Grounding RS-485 C+ Connect to Card Reader RS485+ RS-485 C- Connect to Card Reader RS485- GND Grounding 25 / ● RS-485 card reader ID factory DIP is 1 and 3.
DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description ● 26 the passage exit. UART 1 in the main control board corresponds to the entrance card reader, and UART 5 in the main control board corresponds to the exit card reader. If the user has configured a guest card, the exit needs to be connected to two card readers, one with the DIP 4 and the other with the DIP 3.
DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description ● Power Output 2 RS-232 Interface 5V 5 VDC Power Output G Grounding G Grounding RS-232 G- Connect to RS-232G- RS-232 G+ Connect to Card Reader RS-232G+ G Grounding RS-232 H- Connect to RS-232H- RS-232 H+ Connect to Card Reader RS-232H+ 27 card reader 3. This is the RS-485 interface, which cannot be switched by dialing. / ● ● This is the RS-232 interface, which cannot be switched by dialing.
DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description passes through the embedded pipe and connects with the QR code on the left.
DS-K3Y411X Series Flap Barrier Quick Start Guide Access Control Board Terminal Description D1 controls the door opening for ordinary entrance, and D2 controls the door opening for ordinary exit. D2- Door 2 Relay Output (Dry Contact) If necessary, the door lock relay can be used to control the third-party barrier switch. D1 controls the door opening for ordinary entrance, and D2 controls the door opening for ordinary exit. Alarm Output Relay 1 (Dry Contact) The alarm output supports switch output.
DS-K3Y411X Series Flap Barrier Quick Start Guide ● ● Note You can swtich between RS-485 and RS-232 via the DIP switch on the access control board. For details about DIP switch and swiching method, see Access Control Board UART Description . For details about DIP switch operation, see DIP Switch Description . 4.5.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-12 DIP Switch on Access Control Board DIP A can set the device mode, DIP 2 to 5 can set the RS-485/RS-232 interface, and DIP B can also be used to initialize the device.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 4-13 UART No. Description The corresponding functions of different DIP Switch are described as follows: No. DIP A Device Mode 1 to 2: Work Mode UART No.
DS-K3Y411X Series Flap Barrier Quick Start Guide No. Device Mode UART No.
DS-K3Y411X Series Flap Barrier Quick Start Guide No. Device Mode UART No. Function Binary Value Prohibit Entrance and Controlled Exit Prohibit Entrance and Free Exit DIP B 1 to 3 UART 5 4 to 6 DIP C ON: UART 5 is RS485E Interface / / / Reserved 8 / Default is OFF.
DS-K3Y411X Series Flap Barrier Quick Start Guide Note For proper communication between turnstile and peripherals, DIP Switch No. 1 to 3, 4 to 6, 7, and 8 of DIP B, DIP C, DIP D, and DIP E cannot be turned ON at the same time. The reserved UART terminal positions in the turnstile and their corresponded UART No. are as follows: Note The diagram is for reference only. Figure 4-14 Interface and Corresponded UART No.
DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.7 RS-485 Wiring ● ● Note The RS-485 interfaces are for connecting ID card reader, IC card reader, card reader, card recycler, text screen, and face recognition terminal. Take the wiring of RS-485 card reader as an example. For details about text screen, see Configuring Screen Parameters in User Manual of iVMS-4200 AC Client Software.
DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.8 RS-232 Wiring ● ● ● Note Access control board of pedestal can connect QR code scanner, card recycler, text screen and face recognition terminal via RS-232 interface. For details about text screen, see Configuring Screen Parameters in User Manual of iVMS-4200 AC Client Software. Take the wiring of text screen as an example.
DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.9 Barrier Control Wiring By default, the barrier has connected with the access control board. The lane control board can control the barrier status. If possible, the device can connect with a third party lane control board to control the third party barriers. Interface D1 controls barrier opening for entrance, while interface D2 controls barrier opening for exit. Note Use the jumper cap to switch the relay status.
DS-K3Y411X Series Flap Barrier Quick Start Guide 4.5.10 Alarm Output Wiring Note For details about changing the relay output status via the jumper cap, see Alarm Relay Output Mode (NO/NC) .
DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 5 Device Settings After installation and wiring completed, the turnstile will learn the open and closed position automatically. After the learning, the turnstile is in the normal mode.
DS-K3Y411X Series Flap Barrier Quick Start Guide By default, the keyfob is in one-to-one mode. The keyfob's DIP switch is towards 1 (OFF). The keyfob can control only one turnstile. One-to-Many Mode The keyfob's DIP switch is ON. In this mode, the keyfob can control multiple turnstiles. 1. Power off the turnstile. 2. Set the No.4 switch of the DIP Switch on the access control board to the ON side. 3. Power on the turnstile and it will enter the keyfob pairing mode. 4.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-1 Initialization Jumper Cap 2. Disconnect the power and reboot the device. 3. When the beep stopped, set the No.8 switch to the OFF side, and reboot the turnstile to take effect. 4. Disconnect the power and power on the device again. Caution The initialization of the device will restore all the parameters to the default setting and all the device events are deleted. Note Make sure no persons are in the lane when powering on the device.
DS-K3Y411X Series Flap Barrier Quick Start Guide 5.3 Switch Relay Output Mode (NO/NC) 5.3.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-3 Barrier Opening (NO) The jumper cap position of barrier closing (NC) is as below: Figure 5-4 Barrier Closing (NC) Note The default status is NC. 5.3.
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-5 Jumper Cap Location (Alarm Relay Output Mode) The jumper cap position of alarm opening (NO) is as below: Figure 5-6 Alarm Opening (NO) The jumper cap position of alarm closing (NC) is as below: 45
DS-K3Y411X Series Flap Barrier Quick Start Guide Figure 5-7 Alarm Closing (NC) Note The default status is NO.
DS-K3Y411X Series Flap Barrier Quick Start Guide Chapter 6 Activation You should activate the device before the first login. After powering on the device, the system will switch to Device Activation page. Activation via the device, SADP tool and the client software are supported. The default values of the device are as follows: ● The default IP address: 192.0.0.64 ● The default port No.: 8000 ● The default user name: admin 6.
DS-K3Y411X Series Flap Barrier Quick Start Guide Status of the device becomes Active after successful activation. 5. Modify IP address of the device. 1) Select the device. 2) Change the device IP address to the same subnet as your computer by either modifying the IP address manually or checking Enable DHCP. 3) Input the admin password and click Modify to activate your IP address modification. 6.
DS-K3Y411X Series Flap Barrier Quick Start Guide Caution The password strength of the device can be automatically checked. We highly recommend you change the password of your own choosing (using a minimum of 8 characters, including at least three kinds of following categories: upper case letters, lower case letters, numbers, and special characters) in order to increase the security of your product.
DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix A. DIP Switch Description The DIP switch is on the main lane control board. The left side to the right side is from the low bit to the high bit. When the switch is towards ON, it means the switch is enabled, otherwise, the switch is off. If you set the DIP switch like the figure displayed below, its binary value is 00001100, and its decimal value is 12.
DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix B.
DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix C. Table of Audio Index Related Content Index Content 1 Authenticated. 2 Card No. does not exist. 3 Card No. and fingerprint mismatch. 4 Climbing over the barrier. 5 Reverse passing. 6 Passing timeout. 7 Intrusion. 8 Force accessing. 9 Tailgating. 10 No permissions. 11 Authentication time out. 12 Authentication failed. 13 Expired card. 14 Stay out of time.
DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix D. Error Code Description The swing barrier will display the error code on the seven-segment display if error occurred. Refer to the table below to find the description of each number.
DS-K3Y411X Series Flap Barrier Quick Start Guide Appendix E. Communication Matrix and Device Command Communication Matrix Scan the following QR code to get the device communication matrix. Note that the matrix contains all communication ports of Hikvision access control and video intercom devices. Figure E-1 QR Code of Communication Matrix Device Command Scan the following QR code to get the device common serial port commands.