Quick Start Guide
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 System Wiring
- Chapter 3 Installation
- Chapter 4 General Wiring
- 4.1 Components Introduction
- 4.2 Wiring Electric Supply
- 4.3 Wire Interconnecting Cable
- 4.4 Face Recognition Terminal Power Supply Wiring (Optional)
- 4.5 Terminal Description
- 4.5.1 UART Related Terminal and Position
- 4.5.2 Main Control Board Terminal Description
- 4.5.3 Sub Control Board Terminal Description
- 4.5.4 BUS Terminal Description
- 4.5.5 Access Control Board Terminal Description
- 4.5.6 Access Control Board UART Description
- 4.5.7 RS-485 Wiring
- 4.5.8 RS-232 Wiring
- 4.5.9 Barrier Control Wiring
- 4.5.10 Alarm Output Wiring
- Chapter 5 Device Settings
- Chapter 6 Activation
- Appendix A. DIP Switch Description
- Appendix B. Event and Alarm Type
- Appendix C. Table of Audio Index Related Content
- Appendix D. Error Code Description
- Appendix E. Communication Matrix and Device Command
Figure 2-3 Wire Face Recognion Terminal
Note
●
The f
ace recognion terminal installed on the le pedestal will gain power from the sub
switch, which should connect to high voltage.
●
The suggested inner diameter of the low voltage conduit is larger than 30 mm.
●
The supplied interconnecng cable length is 3.75 m. If you need a longer one, you can extend
the cable by yourself.
●
If you want to bury both of the AC power cord and the low voltage cable at the entrance, the
two cables should be in separated conduits to avoid interference.
●
If more peripherals are required to connect, you should increase the conduit diameter or bury
another conduit for the external cables.
●
The external AC power cord should be double-insulated.
●
The network cable must be CAT5e or the network cable has beer performance. And the
suggested network cable length should be less than 100 m.