Quick Start Guide
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 System Wiring
- Chapter 3 Installation
- Chapter 4 General Wiring
- 4.1 Components Introduction
- 4.2 Wiring Electric Supply
- 4.3 Wire Interconnecting Cable
- 4.4 Face Recognition Terminal Power Supply Wiring (Optional)
- 4.5 Terminal Description
- 4.5.1 UART Related Terminal and Position
- 4.5.2 Main Control Board Terminal Description
- 4.5.3 Sub Control Board Terminal Description
- 4.5.4 BUS Terminal Description
- 4.5.5 Access Control Board Terminal Description
- 4.5.6 Access Control Board UART Description
- 4.5.7 RS-485 Wiring
- 4.5.8 RS-232 Wiring
- 4.5.9 Barrier Control Wiring
- 4.5.10 Alarm Output Wiring
- Chapter 5 Device Settings
- Chapter 6 Activation
- Appendix A. DIP Switch Description
- Appendix B. Event and Alarm Type
- Appendix C. Table of Audio Index Related Content
- Appendix D. Error Code Description
- Appendix E. Communication Matrix and Device Command
Figure 3-2 Dimension
1.
Prepare for the installaon tools, check the components, and prepare for the installaon base.
2.
Drill holes on the ground according to the installaon holes on the pedestals and insert the
expansion sleeves.
3.
According to the entrance and exit marks on the pedestals, move the pedestals to the
corresponded posions.
Note
Make sure the installaon holes on the pedestals and the base are aligned with each other.
4.
Secur
e the pedestals with expansion bolts.
Note
●
The sug
gested expansion bolt's size is M12*150. You can change or transform the expansion
bolt according to your actual needs. But make sure that do not drill through the oor. If the
oor is too so to install, it is suggested to apply the construcon adhesive to strengthen.
●
Do not immerse the pedestal in the water. In special circumstances, the immersed height
should be no more than 150 mm.
●
The installaon footprint is as follows:
DS-K3Y411X Series Flap Barrier Quick Start Guide
8