Quick Start Guide
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 System Wiring
- Chapter 3 Installation
- Chapter 4 General Wiring
- 4.1 Components Introduction
- 4.2 Wiring Electric Supply
- 4.3 Wire Interconnecting Cable
- 4.4 Face Recognition Terminal Power Supply Wiring (Optional)
- 4.5 Terminal Description
- 4.5.1 UART Related Terminal and Position
- 4.5.2 Main Control Board Terminal Description
- 4.5.3 Sub Control Board Terminal Description
- 4.5.4 BUS Terminal Description
- 4.5.5 Access Control Board Terminal Description
- 4.5.6 Access Control Board UART Description
- 4.5.7 RS-485 Wiring
- 4.5.8 RS-232 Wiring
- 4.5.9 Barrier Control Wiring
- 4.5.10 Alarm Output Wiring
- Chapter 5 Device Settings
- Chapter 6 Activation
- Appendix A. DIP Switch Description
- Appendix B. Event and Alarm Type
- Appendix C. Table of Audio Index Related Content
- Appendix D. Error Code Description
- Appendix E. Communication Matrix and Device Command
Chapter 5 Device Sengs
Aer installaon and wiring completed, the turnsle will learn the open and closed posion
automacally.
Aer the learning, the turnsle is in the normal mode. You can also set the turnsle to test mode,
passing mode and memory mode, pair the keyfob, inialize the hardware, switching between
RS-485 communicaon mode and RS-232 communicaon mode, and view relay output NO/NC
diagram by seng the DIP switch on the access control board.
●
Normal Mode: The device will work properly.
●
Test Mode: Test mode is the same as the normal mode except that the device cannot report the
alarm, the event, or the people counng informaon to the center.
●
Passing Mode: There are 9 passing modes, including controlled bi-direcon, controlled entrance
and prohibited exit, controlled entrance and free exit, free bi-direcon, free entrance and
controlled exit, free entrance and prohibited exit, prohibited bi-direcon, prohibited entrance
and free exit.
●
Memory Mode: By default, the memory mode is enabled. When mulple cards are presented
and authencated, it allows mulple persons passing through the lane. When it counts the
passing people number is equal to the card presented mes, or no person passing through the
lane
aer the last person passing, the barriers will be closed.
Note
You can also set the DIP switch on the access control board to control the entrance and exit
c
ontrolling type, keyfob pairing, etc. For details about the DIP switch value, see
Access Control
Board UART Descripon .
5.1 Pair Keyfob
(Oponal)
Pair the remote control to the device through DIP switch to open/close the barrier remotely.
Before You Start
Ask our technique supports or sales and purchase the keyfob.
Steps
Note
●
Up t
o 32 keyfobs can be added to the turnsle.
●
You can set the keyfob to one-to-one mode or one-to-many mode via the DIP switch on the
keyfob. Here takes one-to-one mode as an example to explain. For one-to-many mode, see the
keyfob user manual.
One-to-One Mode
DS-K3Y411X Series Flap Barrier Quick Start Guide
40