Quick Start Guide

By default, the keyfob is in one-to-one mode. The keyfob's DIP switch is towards 1 (OFF). The
keyfob can control only one turnsle.
One-to-Many Mode
The keyfob's DIP switch is ON. In this mode, the keyfob can control mulple turnsles.
1.
Power o the turnsle.
2.
Set the No.4 switch of the DIP Switch on the access control board to the ON side.
3.
P
ower on the turnsle and it will enter the keyfob pairing mode.
4.
Hold the Close buon for more than 10 seconds. Or pair turnsle and keyfob in the client
soware, see Manage Keyfob User of the user manual for more details.
The keyfob's indicator of the will ash twice if the pairing is completed.
5.
Set the No.4 switch to OFF, and reboot the turnsle to take eect.
Note
Only one turnsle can pair the keyfob. If mulple turnsles are in the pairing mode, the
k
eyfob will select only one of them to pair.
For details about DIP switch value and meaning, see
Access Control Board UART Descripon .
6.
Oponal: Go t
o System → User → Keyfob User on the remote control page of the client
soware to delete the keyfob.
5.2 Inialize Device
Steps
1.
Set the No.8 switch of the DIP 2 Switch on the access control board to the ON side.
DS-K3Y411X Series Flap Barrier Quick Start Guide
41