Quick Start Guide
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 System Wiring
- Chapter 3 Installation
- Chapter 4 General Wiring
- 4.1 Components Introduction
- 4.2 Wiring Electric Supply
- 4.3 Wire Interconnecting Cable
- 4.4 Face Recognition Terminal Power Supply Wiring (Optional)
- 4.5 Terminal Description
- 4.5.1 UART Related Terminal and Position
- 4.5.2 Main Control Board Terminal Description
- 4.5.3 Sub Control Board Terminal Description
- 4.5.4 BUS Terminal Description
- 4.5.5 Access Control Board Terminal Description
- 4.5.6 Access Control Board UART Description
- 4.5.7 RS-485 Wiring
- 4.5.8 RS-232 Wiring
- 4.5.9 Barrier Control Wiring
- 4.5.10 Alarm Output Wiring
- Chapter 5 Device Settings
- Chapter 6 Activation
- Appendix A. DIP Switch Description
- Appendix B. Event and Alarm Type
- Appendix C. Table of Audio Index Related Content
- Appendix D. Error Code Description
- Appendix E. Communication Matrix and Device Command
By default, the keyfob is in one-to-one mode. The keyfob's DIP switch is towards 1 (OFF). The
keyfob can control only one turnsle.
One-to-Many Mode
The keyfob's DIP switch is ON. In this mode, the keyfob can control mulple turnsles.
1.
Power o the turnsle.
2.
Set the No.4 switch of the DIP Switch on the access control board to the ON side.
3.
P
ower on the turnsle and it will enter the keyfob pairing mode.
4.
Hold the Close buon for more than 10 seconds. Or pair turnsle and keyfob in the client
soware, see Manage Keyfob User of the user manual for more details.
The keyfob's indicator of the will ash twice if the pairing is completed.
5.
Set the No.4 switch to OFF, and reboot the turnsle to take eect.
Note
●
Only one turnsle can pair the keyfob. If mulple turnsles are in the pairing mode, the
k
eyfob will select only one of them to pair.
●
For details about DIP switch value and meaning, see
Access Control Board UART Descripon .
6.
Oponal: Go t
o System → User → Keyfob User on the remote control page of the client
soware to delete the keyfob.
5.2 Inialize Device
Steps
1.
Set the No.8 switch of the DIP 2 Switch on the access control board to the ON side.
DS-K3Y411X Series Flap Barrier Quick Start Guide
41