User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Wiring
- 2.1 Components Introduction
- 2.2 Wiring Electric Supply
- 2.3 Wire Interconnecting Cable
- 2.4 Terminal Description
- 2.4.1 Master Control Board Terminal Description
- 2.4.2 Slave Control Board Terminal Description
- 2.4.3 Main Control Board Terminal Description
- 2.4.4 Main Control Board Serial Port ID Description
- 2.4.5 RS-485 Wiring
- 2.4.6 RS-232 Wiring
- 2.4.7 Wiegand Wiring
- 2.4.8 Barrier Control Wiring
- 2.4.9 Alarm Output Wiring
- Chapter 3 Installation
- Chapter 4 Device Settings
- Chapter 5 Activation
- Chapter 6 Client Software Configuration
- 6.1 Configuration Flow of Client Software
- 6.2 Device Management
- 6.3 Group Management
- 6.4 Person Management
- 6.4.1 Add Organization
- 6.4.2 Configure Basic Information
- 6.4.3 Issue a Card to One Person
- 6.4.4 Upload a Face Photo from Local PC
- 6.4.5 Take a Photo via Client
- 6.4.6 Collect Face via Access Control Device
- 6.4.7 Collect Fingerprint via Client
- 6.4.8 Collect Fingerprint via Access Control Device
- 6.4.9 Configure Access Control Information
- 6.4.10 Customize Person Information
- 6.4.11 Configure Resident Information
- 6.4.12 Configure Additional Information
- 6.4.13 Import and Export Person Identify Information
- 6.4.14 Import Person Information
- 6.4.15 Import Person Pictures
- 6.4.16 Export Person Information
- 6.4.17 Export Person Pictures
- 6.4.18 Get Person Information from Access Control Device
- 6.4.19 Move Persons to Another Organization
- 6.4.20 Issue Cards to Persons in Batch
- 6.4.21 Report Card Loss
- 6.4.22 Set Card Issuing Parameters
- 6.5 Configure Schedule and Template
- 6.6 Set Access Group to Assign Access Authorization to Persons
- 6.7 Configure Advanced Functions
- 6.7.1 Configure Device Parameters
- 6.7.2 Configure Remaining Open/Closed
- 6.7.3 Configure Multi-Factor Authentication
- 6.7.4 Configure Custom Wiegand Rule
- 6.7.5 Configure Card Reader Authentication Mode and Schedule
- 6.7.6 Configure First Person In
- 6.7.7 Configure Anti-Passback
- 6.7.8 Configure Device Parameters
- 6.8 Configure Linkage Actions for Access Control
- 6.9 Door Control
- 6.10 Event Center
- 6.11 Time and Attendance
- 6.12 Remote Configuration via Client Software
- 6.12.1 Check Device Information
- 6.12.2 Edit Device Name
- 6.12.3 Edit Time
- 6.12.4 Set System Maintenance
- 6.12.5 Configure RS-485 Parameters
- 6.12.6 Manage Network User
- 6.12.7 Manage Keyfob User
- 6.12.8 Set Security
- 6.12.9 Configure Lane Parameters
- 6.12.10 Configure Screen Parameters
- 6.12.11 Configure Screen Parameters
- 6.12.12 Configure Network Parameters
- 6.12.13 Configure Advanced Network
- 6.12.14 Configure Audio File
- 6.12.15 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
Congure Report Display
You can congure display contents displayed in the aendance report, such as the company name,
logo, date format, me format, and mark.
St
eps
1. Enter Time & Aendance module.
2. Click Aendance Stascs → Report Display .
3. Set the display sengs for aendance report.
Company Name
Enter a company name to display the name in the report.
Date Format / Time Format
Set the date format and me format according to the actual needs.
Aendance Status Mark in Report
Enter the mark and select the color. The related elds of aendance status in the report will
display with the mark and color.
Weekend Mark in Report
Enter the mark and select the color. The weekend elds in the report will display with the
mark and color.
4. Click Save.
6.11.2 Add Timetable
You can add the metable for the shi schedule.
St
eps
1. Click Time & Aendance → Timetable to enter metable sengs window.
2. Click Add to enter Add Timetable page.
3. Create a name for the metable.
4. Select
calculaon method.
First In & Last Out
The
rst check-in me is recorded as start work me and the last check-out me is recorded
as the end-work me.
Each Check-In/Out
Each check-in me and check-out me is valid and the sum of all periods between adjacent
check-in and check-out me will be recorded as the valid working duraon.
You need to set Valid Auth. Interval for this calculaon method. For example, if the interval
between card swiping of the same card is less than the set value, the card swiping is invalid.
5. Oponal: Se
t Enable T&A Status switch to on to calculate according to aendance status of the
device.
DS-K3Y501 Flap Barrier User Manual
88