User's Manual

Table Of Contents
Note
Do not power o
during the upgrading.
6.12.5
Congure RS-485 Parameters
You can set the RS-485 parameters including the baud rate, data bit, stop bit, parity type,
communicaon mode, work mode, and connecon mode.
Steps
1. Click Maintenance and Management → Device to enter the device list.
2. Click
to enter the remote conguraon page.
3. Click S
ystem → RS-485 Sengs to enter the Conguring the RS-485 Parameters tab.
4. Select the serial No. of the port from the dropdown list to set the RS-485 parameters.
5. Set the baud rate, data bit, the stop bit, parity, ow control, communicaon mode, working
mode, and the connecon mode from the dropdown list.
6. Click Save and the congured parameters will be applied to the device automacally.
Note
Aer changing the working mode, the device will be rebooted. A prompt will be popped up
aer changing the working mode.
6.12.6 Manage Network User
Steps
1. Click Main
tenance and Management → Device to enter the device list.
2. Click
to enter the remote conguraon page.
3. Click S
ystem → User → Network User .
4. Click Add to add the user.
5. Oponal: Select a user in the user lis
t and click Edit to edit the user.
You are able to edit the user password, the IP address, the MAC address and the user
permission.
6. Click OK.
6.12.7 Manage Keyfob User
Steps
1. Click Main
tenance and Management → Device to enter the device list.
2. Click
to enter the remote conguraon page.
3. Click S
ystem → User → Keyfob User .
4. Click Add to add the user.
5. Check Enable in the pop-up window and set the keyfob's serial No.
DS-K3Y501 Flap Barrier User Manual