User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Wiring
- 2.1 Components Introduction
- 2.2 Wiring Electric Supply
- 2.3 Wire Interconnecting Cable
- 2.4 Terminal Description
- 2.4.1 Master Control Board Terminal Description
- 2.4.2 Slave Control Board Terminal Description
- 2.4.3 Main Control Board Terminal Description
- 2.4.4 Main Control Board Serial Port ID Description
- 2.4.5 RS-485 Wiring
- 2.4.6 RS-232 Wiring
- 2.4.7 Wiegand Wiring
- 2.4.8 Barrier Control Wiring
- 2.4.9 Alarm Output Wiring
- Chapter 3 Installation
- Chapter 4 Device Settings
- Chapter 5 Activation
- Chapter 6 Client Software Configuration
- 6.1 Configuration Flow of Client Software
- 6.2 Device Management
- 6.3 Group Management
- 6.4 Person Management
- 6.4.1 Add Organization
- 6.4.2 Configure Basic Information
- 6.4.3 Issue a Card to One Person
- 6.4.4 Upload a Face Photo from Local PC
- 6.4.5 Take a Photo via Client
- 6.4.6 Collect Face via Access Control Device
- 6.4.7 Collect Fingerprint via Client
- 6.4.8 Collect Fingerprint via Access Control Device
- 6.4.9 Configure Access Control Information
- 6.4.10 Customize Person Information
- 6.4.11 Configure Resident Information
- 6.4.12 Configure Additional Information
- 6.4.13 Import and Export Person Identify Information
- 6.4.14 Import Person Information
- 6.4.15 Import Person Pictures
- 6.4.16 Export Person Information
- 6.4.17 Export Person Pictures
- 6.4.18 Get Person Information from Access Control Device
- 6.4.19 Move Persons to Another Organization
- 6.4.20 Issue Cards to Persons in Batch
- 6.4.21 Report Card Loss
- 6.4.22 Set Card Issuing Parameters
- 6.5 Configure Schedule and Template
- 6.6 Set Access Group to Assign Access Authorization to Persons
- 6.7 Configure Advanced Functions
- 6.7.1 Configure Device Parameters
- 6.7.2 Configure Remaining Open/Closed
- 6.7.3 Configure Multi-Factor Authentication
- 6.7.4 Configure Custom Wiegand Rule
- 6.7.5 Configure Card Reader Authentication Mode and Schedule
- 6.7.6 Configure First Person In
- 6.7.7 Configure Anti-Passback
- 6.7.8 Configure Device Parameters
- 6.8 Configure Linkage Actions for Access Control
- 6.9 Door Control
- 6.10 Event Center
- 6.11 Time and Attendance
- 6.12 Remote Configuration via Client Software
- 6.12.1 Check Device Information
- 6.12.2 Edit Device Name
- 6.12.3 Edit Time
- 6.12.4 Set System Maintenance
- 6.12.5 Configure RS-485 Parameters
- 6.12.6 Manage Network User
- 6.12.7 Manage Keyfob User
- 6.12.8 Set Security
- 6.12.9 Configure Lane Parameters
- 6.12.10 Configure Screen Parameters
- 6.12.11 Configure Screen Parameters
- 6.12.12 Configure Network Parameters
- 6.12.13 Configure Advanced Network
- 6.12.14 Configure Audio File
- 6.12.15 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
Figure 2-4 Wire General Device
Note
• The supplied interconnecng cable length is 3.75 m. If you need a longer one, ask our technique
supports or sales and pur
chase for 5.5 m interconnecng cables.
• The suggested inner diameter of the low voltage conduit is larger than 30 mm.
• If you want to bury both of the AC power cord and the low voltage cable at the entrance, the
two cables should be in separated conduits to avoid interference.
• If more peripherals are required to connect, you should increase the conduit diameter or bury
another conduit for the external cables.
• The external AC power cord should be double-insulated.
• The suggested network cable should be CAT5e or the network cable has beer performance.
And the sug
gested network cable length should be less than 100 m.
2.3.2 Wire Face Recognion Terminal
The picture displayed below describes the interconnecng cable's wiring diagram.
DS-K3Y501 Flap Barrier User Manual
6