User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Wiring
- 2.1 Components Introduction
- 2.2 Wiring Electric Supply
- 2.3 Wire Interconnecting Cable
- 2.4 Terminal Description
- 2.4.1 Master Control Board Terminal Description
- 2.4.2 Slave Control Board Terminal Description
- 2.4.3 Main Control Board Terminal Description
- 2.4.4 Main Control Board Serial Port ID Description
- 2.4.5 RS-485 Wiring
- 2.4.6 RS-232 Wiring
- 2.4.7 Wiegand Wiring
- 2.4.8 Barrier Control Wiring
- 2.4.9 Alarm Output Wiring
- Chapter 3 Installation
- Chapter 4 Device Settings
- Chapter 5 Activation
- Chapter 6 Client Software Configuration
- 6.1 Configuration Flow of Client Software
- 6.2 Device Management
- 6.3 Group Management
- 6.4 Person Management
- 6.4.1 Add Organization
- 6.4.2 Configure Basic Information
- 6.4.3 Issue a Card to One Person
- 6.4.4 Upload a Face Photo from Local PC
- 6.4.5 Take a Photo via Client
- 6.4.6 Collect Face via Access Control Device
- 6.4.7 Collect Fingerprint via Client
- 6.4.8 Collect Fingerprint via Access Control Device
- 6.4.9 Configure Access Control Information
- 6.4.10 Customize Person Information
- 6.4.11 Configure Resident Information
- 6.4.12 Configure Additional Information
- 6.4.13 Import and Export Person Identify Information
- 6.4.14 Import Person Information
- 6.4.15 Import Person Pictures
- 6.4.16 Export Person Information
- 6.4.17 Export Person Pictures
- 6.4.18 Get Person Information from Access Control Device
- 6.4.19 Move Persons to Another Organization
- 6.4.20 Issue Cards to Persons in Batch
- 6.4.21 Report Card Loss
- 6.4.22 Set Card Issuing Parameters
- 6.5 Configure Schedule and Template
- 6.6 Set Access Group to Assign Access Authorization to Persons
- 6.7 Configure Advanced Functions
- 6.7.1 Configure Device Parameters
- 6.7.2 Configure Remaining Open/Closed
- 6.7.3 Configure Multi-Factor Authentication
- 6.7.4 Configure Custom Wiegand Rule
- 6.7.5 Configure Card Reader Authentication Mode and Schedule
- 6.7.6 Configure First Person In
- 6.7.7 Configure Anti-Passback
- 6.7.8 Configure Device Parameters
- 6.8 Configure Linkage Actions for Access Control
- 6.9 Door Control
- 6.10 Event Center
- 6.11 Time and Attendance
- 6.12 Remote Configuration via Client Software
- 6.12.1 Check Device Information
- 6.12.2 Edit Device Name
- 6.12.3 Edit Time
- 6.12.4 Set System Maintenance
- 6.12.5 Configure RS-485 Parameters
- 6.12.6 Manage Network User
- 6.12.7 Manage Keyfob User
- 6.12.8 Set Security
- 6.12.9 Configure Lane Parameters
- 6.12.10 Configure Screen Parameters
- 6.12.11 Configure Screen Parameters
- 6.12.12 Configure Network Parameters
- 6.12.13 Configure Advanced Network
- 6.12.14 Configure Audio File
- 6.12.15 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
The keyfob's indicator of the will ash twice if the pairing is completed.
5. Set the DIP switch as OFF, and reboot the turnsle to take eect.
Note
• You can also pair the keyfob via the client soware. For details, see Managing K
eyfob in User
Manual of iVMS-4200 AC Client Soware.
• Only one turnsle can pair the keyfob. If mulple turnsles are in the pairing mode, the
keyfob will select only one of them to pair.
• For details about DIP switch value and meaning, see DIP Switch .
4.2 Inialize Device
Steps
1. R
emove the JP11 jumper cap on the main control board.
Figure 4-1
Inializaon Jumper Cap
2. Disconnect the power and reboot the device. The device buzzer buzzes a long beep.
3. When the beep stopped, plug the jumper cap back.
4. Disconnect the power and power on the device again.
Cauon
The
inializaon of the device will restore all the parameters to the default seng and all the
device events are deleted.
Note
Make sure no persons are in the lane when powering on the device.