User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Wiring
- 2.1 Components Introduction
- 2.2 Wiring Electric Supply
- 2.3 Wire Interconnecting Cable
- 2.4 Terminal Description
- 2.4.1 Master Control Board Terminal Description
- 2.4.2 Slave Control Board Terminal Description
- 2.4.3 Main Control Board Terminal Description
- 2.4.4 Main Control Board Serial Port ID Description
- 2.4.5 RS-485 Wiring
- 2.4.6 RS-232 Wiring
- 2.4.7 Wiegand Wiring
- 2.4.8 Barrier Control Wiring
- 2.4.9 Alarm Output Wiring
- Chapter 3 Installation
- Chapter 4 Device Settings
- Chapter 5 Activation
- Chapter 6 Client Software Configuration
- 6.1 Configuration Flow of Client Software
- 6.2 Device Management
- 6.3 Group Management
- 6.4 Person Management
- 6.4.1 Add Organization
- 6.4.2 Configure Basic Information
- 6.4.3 Issue a Card to One Person
- 6.4.4 Upload a Face Photo from Local PC
- 6.4.5 Take a Photo via Client
- 6.4.6 Collect Face via Access Control Device
- 6.4.7 Collect Fingerprint via Client
- 6.4.8 Collect Fingerprint via Access Control Device
- 6.4.9 Configure Access Control Information
- 6.4.10 Customize Person Information
- 6.4.11 Configure Resident Information
- 6.4.12 Configure Additional Information
- 6.4.13 Import and Export Person Identify Information
- 6.4.14 Import Person Information
- 6.4.15 Import Person Pictures
- 6.4.16 Export Person Information
- 6.4.17 Export Person Pictures
- 6.4.18 Get Person Information from Access Control Device
- 6.4.19 Move Persons to Another Organization
- 6.4.20 Issue Cards to Persons in Batch
- 6.4.21 Report Card Loss
- 6.4.22 Set Card Issuing Parameters
- 6.5 Configure Schedule and Template
- 6.6 Set Access Group to Assign Access Authorization to Persons
- 6.7 Configure Advanced Functions
- 6.7.1 Configure Device Parameters
- 6.7.2 Configure Remaining Open/Closed
- 6.7.3 Configure Multi-Factor Authentication
- 6.7.4 Configure Custom Wiegand Rule
- 6.7.5 Configure Card Reader Authentication Mode and Schedule
- 6.7.6 Configure First Person In
- 6.7.7 Configure Anti-Passback
- 6.7.8 Configure Device Parameters
- 6.8 Configure Linkage Actions for Access Control
- 6.9 Door Control
- 6.10 Event Center
- 6.11 Time and Attendance
- 6.12 Remote Configuration via Client Software
- 6.12.1 Check Device Information
- 6.12.2 Edit Device Name
- 6.12.3 Edit Time
- 6.12.4 Set System Maintenance
- 6.12.5 Configure RS-485 Parameters
- 6.12.6 Manage Network User
- 6.12.7 Manage Keyfob User
- 6.12.8 Set Security
- 6.12.9 Configure Lane Parameters
- 6.12.10 Configure Screen Parameters
- 6.12.11 Configure Screen Parameters
- 6.12.12 Configure Network Parameters
- 6.12.13 Configure Advanced Network
- 6.12.14 Configure Audio File
- 6.12.15 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
Cauon
The password strength of the device can be automacally checked. We highly recommend
y
ou change the password of your own choosing (using a minimum of 8 characters, including
at least three kinds of following categories: upper case leers, lower case leers, numbers,
and special characters) in order to increase the security of your product. And we recommend
you reset your password regularly, especially in the high security system, reseng the
password monthly or weekly can beer protect your product.
Proper conguraon of all passwords and other security sengs is the responsibility of the
installer and/or end-user.
7. Oponal: Check S
ynchronize Time to synchronize the device me with the PC running the client
aer adding the devices to the client.
8. Oponal: Check Import to Group to create a group by the device name.
Note
You can import all the channels of the device to the corresponding group by default.
9. Click OK t
o add the devices.
Add Device by IP Address or Domain Name
When you know the IP address or domain name of the device to add, you can add devices to the
client by specifying the IP address (or domain name), user name, password, and other related
parameters.
Steps
1. Enter Device Management module.
2. Oponal: Click
on the right of De
vice Management and select Device.
The added devices are displayed in the list.
3. Click Add to open the Add window.
4. Select IP/Domain as the adding mode.
5. Enter the required informaon, including name, address, port number, user name, and
pass
word.
Name
Create a descripve name for the device. For example, you can use a name that can show
the
locaon or feature of the device.
Address
The IP address or domain name of the device.
Port
The devices to add have the same port No. The default value is 8000.
User Name
DS-K3Y501 Flap Barrier User Manual
33










