3. Edit the card reader basic parameters in the Basic Informaon page.
Note
The displayed parameters may vary for dierent access control devices. There are part of
par
ameters listed as follows. Refer to the user manual of the device for more details.
Name
E
dit the card reader name as desired.
Minimum Card Swiping Interval
If the interval between card swiping of the same card is less than the set value, the card
swiping is invalid. You can set it as 0 to 255.
Alarm of Max. Failed Aempts
Enable to report alarm when the card reading aempts reach the set value.
Card Reader Type/Card Reader Descripon
Get card reader type and descripon. They are read-only.
4. Oponal: Some of the following parameters are not listed in the Basic Informaon page, click
More to edit the parameters.
Enable Card Reader
If enabling the funcon, user can present card on the card reader. If disabling the funcon,
the card reader for entrance cannot be used.
OK LED P
olarity/Error LED Polarity/Buzzer Polarity
Set OK LED Polarity/Error LED Polarity/Buzzer LED Polarity of main board according to the
card reader parameters. Generally, adopts the default sengs.
Buzzing Time
Se
t the card reader buzzing me. The available me ranges from 0 to 5,999s. 0 represents
connuous buzzing.
Ma
x. Interval When Entering PWD
When you inpung the password on the card reader, if the interval between pressing two
digits is larger than the set value, the digits you pressed before will be cleared automacally.
Tampering Detecon
Enable the an-tamper
detecon for the card reader.
Communicate with Controller Every
When the access control device cannot connect with the card reader for longer than the set
me, the card reader will turn oine
automacally.
Fingerprint Recognion Level
Select the ngerprint recognion level in the drop-down list.
5. Click OK.