User's Manual
Table Of Contents
- Legal Information
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Wiring
- 2.1 Components Introduction
- 2.2 Wiring Electric Supply
- 2.3 Wire Interconnecting Cable
- 2.4 Terminal Description
- 2.4.1 Master Control Board Terminal Description
- 2.4.2 Slave Control Board Terminal Description
- 2.4.3 Main Control Board Terminal Description
- 2.4.4 Main Control Board Serial Port ID Description
- 2.4.5 RS-485 Wiring
- 2.4.6 RS-232 Wiring
- 2.4.7 Wiegand Wiring
- 2.4.8 Barrier Control Wiring
- 2.4.9 Alarm Output Wiring
- Chapter 3 Installation
- Chapter 4 Device Settings
- Chapter 5 Activation
- Chapter 6 Client Software Configuration
- 6.1 Configuration Flow of Client Software
- 6.2 Device Management
- 6.3 Group Management
- 6.4 Person Management
- 6.4.1 Add Organization
- 6.4.2 Configure Basic Information
- 6.4.3 Issue a Card to One Person
- 6.4.4 Upload a Face Photo from Local PC
- 6.4.5 Take a Photo via Client
- 6.4.6 Collect Face via Access Control Device
- 6.4.7 Collect Fingerprint via Client
- 6.4.8 Collect Fingerprint via Access Control Device
- 6.4.9 Configure Access Control Information
- 6.4.10 Customize Person Information
- 6.4.11 Configure Resident Information
- 6.4.12 Configure Additional Information
- 6.4.13 Import and Export Person Identify Information
- 6.4.14 Import Person Information
- 6.4.15 Import Person Pictures
- 6.4.16 Export Person Information
- 6.4.17 Export Person Pictures
- 6.4.18 Get Person Information from Access Control Device
- 6.4.19 Move Persons to Another Organization
- 6.4.20 Issue Cards to Persons in Batch
- 6.4.21 Report Card Loss
- 6.4.22 Set Card Issuing Parameters
- 6.5 Configure Schedule and Template
- 6.6 Set Access Group to Assign Access Authorization to Persons
- 6.7 Configure Advanced Functions
- 6.7.1 Configure Device Parameters
- 6.7.2 Configure Remaining Open/Closed
- 6.7.3 Configure Multi-Factor Authentication
- 6.7.4 Configure Custom Wiegand Rule
- 6.7.5 Configure Card Reader Authentication Mode and Schedule
- 6.7.6 Configure First Person In
- 6.7.7 Configure Anti-Passback
- 6.7.8 Configure Device Parameters
- 6.8 Configure Linkage Actions for Access Control
- 6.9 Door Control
- 6.10 Event Center
- 6.11 Time and Attendance
- 6.12 Remote Configuration via Client Software
- 6.12.1 Check Device Information
- 6.12.2 Edit Device Name
- 6.12.3 Edit Time
- 6.12.4 Set System Maintenance
- 6.12.5 Configure RS-485 Parameters
- 6.12.6 Manage Network User
- 6.12.7 Manage Keyfob User
- 6.12.8 Set Security
- 6.12.9 Configure Lane Parameters
- 6.12.10 Configure Screen Parameters
- 6.12.11 Configure Screen Parameters
- 6.12.12 Configure Network Parameters
- 6.12.13 Configure Advanced Network
- 6.12.14 Configure Audio File
- 6.12.15 View Relay Status
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. DIP Switch
- Appendix C. Event and Alarm Type
- Appendix D. Table of Audio Index Related Content
1. Click Access Control → Advanced Funcon → Cus
tom Wiegand to enter the Custom Wiegand
page.
2. Select a custom Wiegand on the le.
3. Create a Wiegand name.
Note
Up to 32 characters are allowed in the custom Wiegand name.
4. Click Select De
vice to select the access control device for seng the custom wiegand.
5. Set the parity mode according to the property of the third party card reader.
Note
• Up to 80 bits are allowed in the total length.
•
The odd parity start bit, the odd parity length, the even parity start bit and the even parity
length range from 1 to 80 bit.
• The start bit of the card ID, the manufacturer code, the site code, and the OEM should range
from 1 to 80 bit.
6. Se
t output transformaon rule.
1) Click Set Rule to open the Set Output Transformaon Rules window.
Figure 6-3 Set Output Transformaon Rule
2) Select rules on the le list.
The select
ed rules will be added to the right list.
3) Oponal: Dr
ag the rules to change the rule order.
4) Click OK.
DS-K3Y501 Flap Barrier User Manual
66