3. Select the current mode as Enable Remaining Open aer First Person, Disable R
emaining Open
aer First Person, or Authorizaon by First Person from the drop-down list for each access
control point of the selected device.
Enable Remaining Open aer First Person
The door remains open for the congured me duraon aer the rst person is authorized
unl the remain open duraon ends. If you select this mode, you should set the remain open
duraon.
Note
The remain open duraon should be between 0 and 1440 minutes. By default, the remain
open duraon is 10 minutes.
Disable Remaining Open aer First Person
Disable the funcon of rst person in, namely normal authencaon.
Authoriz
aon by First Person
All authencaons (except for the authencaons of super card, super password, duress
card, and duress code) are allowed only aer the rst person authorizaon.
Note
You can authencate by the rst person again to disable the rst person mode.
4. Click Add on the Fir
st Person List panel.
5. Select person(s) in the le list and the person(s) will be add to the selected persons as the rst
person(s) of the doors.
The added rst person(s) will list in the First Person List
6. Oponal: Select a
rst person from the list and click Delete to remove the person from the rst
person list.
7. Click Save.
6.7.7 Congure
An-Passback
You can set to only pass the access control point according to the specied path and only one
person could pass the access control point aer swiping the card.
Before You Start
Enable the an-passing back funcon of the access control device.
P
erform this task when you want to congure the an-passing back for the access control device.
DS-K3Y501 Flap Barrier User Manual