User's Manual

Table Of Contents
Chapter 3 Installaon
3.1 Installaon Environment
Avoid backlight, direct sunlight, and indirect sunlight.
For
beer face recognion, there should be light source in or near the installaon environment.
Sunlight, wind, hot/cool air from air
condioner and other external factors, which may aect
surface temperature, will create the deviaon of the temperature measurement. In order to get
an accurate result, make sure the device is applied indoors and windlessly (where is relavely
isolated from the outdoors). The working temperature should keep between 10 °C and 35 °C. If
there are no suitable environments for temperature measurement (the area faces the indoor
and connects the outdoor, the area at the door of the indoor environment, etc.), building a
temporary temperature measurement environment is suggested.
Inuence Factors of Temperature Measurement:
Wind: The wind will take the heat away, which may
aect the measurement result.
Sweat: The sweat will take the heat away, which may aect the measurement result.
Air Condioner (Cool Air): If the indoor temperature is low, the surface temperature may also
lower than the actual temperature, which may
aect the measurement result.
Air Condioner (Heat) or Heang: If the indoor temperature is high, the surface temperature
may also higher than the actual temperature, which may
aect the measurement result.
In order to make the device work properly, you should wait for 90 min aer the device is
powered on.
For details about
installaon environment, see Tips for Installaon Environment .
3.2
Installaon
Steps
1.
Put the device on the surface.
Note
This equipment is suitable for mounng on concrete or other non-combusble surface only.
2.
Plug the power supply in the power interface.
3.
Press the power switch to power on the device.
The device will enter the main page
aer powering on.
4.
Oponal: Connect th device with the network.
DS-K5032-3XFD Visitor Terminal User Manual
4