User's Manual

Table Of Contents
3.2.2 Flush Mounng with Gang Box
Steps
1.
Drill a hole in the w
al for inserng the gang box. The size of the hole should be
lar
ger than that of the gang box. The suggested size of the hole is 404.5 (W) ×
123.5 (H) × 48 (D) mm.
Figure 3-7 Drill an Installaon Hole
2.
Insert the g
ang box into the hole and x it with 4 PA4 screws. Make sure the
edg
es of the gang box align to the wall.
Figure 3-8 Insert the Gang Box
3.
R
oute the cables of the door staon through the cable hole.
Video Intercom D Series Door Staon User Manual
17