User's Manual

Table Of Contents
Note
The dimension of the g
ang box is 364 mm (W) × 118 mm (H) × 40 mm (D).
The
installaon hole should be bigger than the actual size. The suggested
dimension of the installaon hole is 364.3 mm (W) × 118.6 mm (H) × 40.2 mm
(D).
3.2 Flush Mounng with Gang Box
Steps
1.
Ca
ve an installaon hole in the wall. Pull the cable out from the wall.
Note
The sug
gested dimension of the installaon hole is 364.3 mm (W) × 118.6
mm (H) × 40.2 mm (D).
The sug
gested length of the cables le outside is 250 mm.
2.
Ins
tall the gang box into the wall.
1) Remove the plasc sheet of the gang box with the tool.
2)
Insert the gang box into the installaon hole. Mark the gang box screw holes'
posion with a marker, and take out the gang box.
3) Drill 4 holes according to the marks on the wall, and insert the expansion
sleeves into the screw holes.
4) Fix the gang box with 4 expansion bolts.
3.
Fix the gap between the gang box and wall with concrete. Remove the mounng
ears with tool aer concrete is dry. Connect the cables according to the Wiring
Descripon.
4.
Insert the door
staon into the gang box. Slide the door staon down and x it
with 2 set screws. Apply Silicone sealant among the joints between the device
and the wall (except the lower side) to keep the raindrop from entering.
Video Intercom Face Recognion Door Staon with 4.3-inch Screen User Manual
9