Figure 5-1 Wall Mounng Plate
Steps
1.
Chisel a hole in the w
all. The size of the hole should be 76 mm (width) × 76 mm (length) × 50
mm (depth).
2.
Insert the juncon box to the hole chiseled on the wall.
3.
Fix the w
all mounng plate to the juncon box with 2 screws.
4.
Hook the indoor staon to the wall mounng plate ghtly by inserng the plate hooks into the
slots on the rear panel of the indoor staon, during which the lock catch will be locked
automacally.
Video Intercom Bundle