Figure 5-19 Elevator Control
2.
Check t
o enable eleva
tor control function.
3.
Select an Elevat
or No., and select an elevator controller type for the elevator.
4.
Set the
Negative Floor.
5.
Select the Interface T
ype as RS-485 or Network Interface. And enable the
elevator control.
-
If you select RS-485, make sure you have connected the door station to the
ele
v
a
t
or controller with RS-485 wire.
-
If you select Network interface, enter the elevator controller's IP address,
port No., user name, and password.
6.
Click Save to enable the settings.
Note
Up to 4 eleva
tor controllers can be connected to one door station.
Up t
o 10
neg
ativ
e floors can be added.
Make sure the int
erface types of elevator controllers, which are connected
to the same door station are consistent.
Video Intercom Villa Door Station User Manual