Video Intercom Villa Door Staon
Diagram References
ENGLISH
Appearance
Indicator Descripon
Installaon Accessory
Acvate Device via Web
Before you begin:
Surface Mounng without Protecve Shield
Surface Mounng without Protecve Shield
1
3
Installaon
4
Terminal and Wiring
2
Microphone
Camera
Indicator
Unlock : Green Call: Orange Communicate: White
1 2
Mounng Template
Mounng Plate
1 2
3
4
9
11
5
7
10
8
Make sure all related equipments are power-off during the installaon.
Tools that you need to prepare for installaon:
Drill (ø2.846) and gradienter.
Purchase the protecve shield before installaon.
1. Sck the mounng template on the wall. Drill screw holes according to the mounng
template.
Remove the template from the wall.
2. Secure the mounng plate on the wall with 4 supplied screws according to the screw
holes.
3. Install the villa door staon to the mounng plate. Fix the device on the mounng
plate with the set screw.
Surface Mounng with Protecve Shield
Surface Mounng with Protecve Shield
1. Sck the mounng template on the wall. Drill screw holes according to the mounng
template.
Remove the template from the wall.
2. Align the protecve shield with the mounng template.
3. Secure the mounng plate and protecve shield on the wall with 4 supplied screws
according to the screw holes.
4. Install the villa door staon to the mounng plate. Fix the device on the mounng
plate with the set screw.
1. Power on the device, and connect the device to the network.
2. Enter the IP address into the address bar of the web browser, and click Enter to enter the
acvaon page.
Note:The computer and the device should belong to the same subnet.
3. Create and enter a password into the password field.
4. Confirm the password.
5. Click OK to acvate the device.
Note: When the device is not acvated, the basic operaon and remote configuraon of device cannot be
performed.
You are required to acvate the device first by seng a strong password for it before
you can use the device.
Default parameters of door staon are as follows:
Default IP Address: 192.0.0.65.
Default Port No.: 8000.
Default User Name: admin.
Access to the Device by Web Browsers
1. In the browser address bar, enter the IP address of the device, and press
the Enter key to enter the login page.
2. Enter the user name and password and click Login.
Unlock Door
Aer issuing cards, you can unlock the door by presenng the issued card.
Terminals
TF Card Slot 12 Network Interface
Buon
Loudspeaker
6
Card Reading Area
TAMPER
NC: Door Lock Relay Output (NC)
NO: Door Lock Relay Output (NO)
COM: Common Interface
GND: Grounding
12 VDC IN: Power Supply Input
AIN1: For the access of Door Contact
AIN3: For the access of Exit Buon
AIN2 & AIN4: Reserved
485-: RS-485 Interface (Reserved)
485+: RS-485 Interface (Reserved)
Set Screw
Debugging Port
Note: Debugging port is used for debugging only.
Note: Video intercom villa door staon supports flush mounng and surface mounng.
Note: The dimension of the mounng plate is 102.58 mm × 39.24 mm × 6.2 mm.
Note: Configure the room No. of the indoor staon which is linked to the villa door staon. Refer to Video Intercom
Indoor Staon User Manual for details.
Configuraon via Web5
Refer to Video Intercom Villa Door Staon User Manual (scan the QR code) for details.
Only Mifare card supported, and Mifare card with non-standard shape is recommended.
Up to 256 cards can be issued and managed by V series door staon. A voice prompt (No more cards can be
issued.) can be heard when the issued card amount exceeds the upper limit.
UD16091B-B
4
1
2 3
1
1
1
2
Communicate with Indoor Staon
1. Click Sengs → Intercom → Press Buon to Call to enter the sengs page.
2. Set the parameters.
-Edit call No. for every buon.
-Check Call Management Center to set the buon calling center.
Note: If you check Call Management Center and set the call No. as well, call management center has higher privilege
than call No.
3. Press buon to call indoor staon.
3
5
3
4
2
5
Product Informaon
Activation
User Name
Password
Confirm
OK
1. Click Sengs → Access Control and Elevator Control to enter the corresponding sengs
page.
2. Click Issue Card. Present the card on the card reading area.
3. When issuing finished, the windows pop up on the sengs page.
Issue Card
4
1
2
3
4
7
8
9
10
6
5
11 12
RS-485+
RS-485-
Orange
Yellow
Red
DC 12V IN
GND
AIN1
AIN2
AIN3
AIN4
NC
NO
Black
White
White
White
Yellow
Blue
COMGreen
GND
GND
Black
Black
White
PRESS
Exit Button
TO EXIT
Reserved
Power
Input
The re commend ed distanc e from the gro und leve l is 1.40
adju stable d epends on t he height of b ody.
102023104
Hole1
Hole2
Hole1
Hole1 Hole1
102.58
1.18
Unit : mm
6.2
39.24
3.45
2
1
3
ScrewsScrew
Villa Door Station
Mounting Plate Mounting Template Wall
1
3
4
2
Screws
Screws
Screw
Villa Door Station
Mounting Plate Protective Shield Mounting Template Wall
©2019 Hangzhou Hikvision Digital Technology Co., Ltd.
It includes instrucons on how to use the Product. The soware embodied in the Product is governed by the user license agreement
covering that Product.
About this Manual
This Manual is subject to domesc and internaonal copyright protecon. Hangzhou Hikvision Digital Technology Co., Ltd. (“Hikvision”)
reserves all rights to this manual. This manual cannot be reproduced, changed, translated, or distributed, parally or wholly, by any
means, without the prior wrien permission of Hikvision.
Trademarks
and other Hikvision marks are the property of Hikvision and are registered trademarks or the subject of applicaons for the
same by Hikvision and/or its affiliates. Other trademarks menoned in this manual are the properes of their respecve owners. No
right of license is given to use such trademarks without express permission.
Legal Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND
FIRMWARE, IS PROVIDED “AS IS”, WITH ALL FAULTS AND ERRORS, AND HIKVISION MAKES NO WARRANTIES, EXPRESS OR IMPLIED,
INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, FITNESS FOR A PARTICULAR PURPOSE, AND
NON-INFRINGEMENT OF THIRD PARTY. IN NO EVENT WILL HIKVISION, ITS DIRECTORS, OFFICERS, EMPLOYEES, OR AGENTS BE LIABLE TO
YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF
BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA OR DOCUMENTATION, IN CONNECTION WITH THE USE OF THIS
PRODUCT, EVEN IF HIKVISION HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
REGARDING TO THE PRODUCT WITH INTERNET ACCESS, THE USE OF PRODUCT SHALL BE WHOLLY AT YOUR OWN RISKS. HIKVISION
SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING FROM CYBER
ATTACK, HACKER ATTACK, VIRUS INSPECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY
TECHNICAL SUPPORT IF REQUIRED.
SURVEILLANCE LAWS VARY BY JURISDICTION. PLEASE CHECK ALL RELEVANT LAWS IN YOUR JURISDICTION BEFORE USING THIS PRODUCT
IN ORDER TO ENSURE THAT YOUR USE CONFORMS THE APPLICABLE LAW. HIKVISION SHALL NOT BE LIABLE IN THE EVENT THAT THIS
PRODUCT IS USED WITH ILLEGITIMATE PURPOSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATER PREVAILS.
Data Protecon
During the use of device, personal data will be collected, stored and processed. To protect data, the development of Hikvision devices
incorporates privacy by design principles. For example, for device with facial recognion features, biometrics data is stored in your
device with encrypon method; for fingerprint device, only fingerprint template will be saved, which is impossible to reconstruct a
fingerprint image.
As data controller, you are advised to collect, store, process and transfer data in accordance with the applicable data protecon laws and
regulaons, including without limitaon, conducng security controls to safeguard personal data, such as, implemenng reasonable
administrave and physical security controls, conduct periodic reviews and assessments of the effecveness of your security controls.
Scan the QR code to get the user manual for detailed inforamon.
This product and - if applicable - the supplied accessories too are marked with "CE" and comply therefore with the applicable
harmonized European standards listed under the RE Direcve 2014/53/EU, the EMC Direcve 2014/30/EU, the RoHS Direcve
2011/65/EU.
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be disposed of as unsorted municipal waste in the
European Union. For proper recycling, return this product to your local supplier upon the purchase of equivalent new
equipment, or dispose of it at designated collecon points. For more informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be disposed of as unsorted municipal waste in the
European Union. See the product documentaon for specific baery informaon. The baery is marked with this symbol, which
may include leering to indicate cadmium (Cd), lead (Pb), or mercury (Hg). For proper recycling, return the baery to your
supplier or to a designated collecon point. For more informaon see: www.recyclethis.info
FCC Conditions
This device complies with part 15 of the FCC Rules. Operaon is subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including interference that may cause undesired operaon.
EU Conformity Statement
FCC Information
Please take aenon that changes or modificaon not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC compliance: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protecon against harmful interference in a residenal installaon. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instrucons, may cause harmful interference to radio communicaons. However, there is no guarantee that
interference will not occur in a parcular installaon. If this equipment does cause harmful interference to radio or television recepon, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
Vaild password range [8-16]. You can
use a combinaon of numbers,
lowercase, uppercase and special
character for your password with at
least two kinds of them contained.
Buon Sengs
Buon
1 0
Call Call Management Center
DS-KV6103-PE1 DS-KV6113-WPE1
IC statement
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is subject to the following two condions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitaon est autorisée aux deux condions
suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d'en compromere le fonconnement.
Under Industry Canada regulaons, this radio transmier may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmier by
Industry Canada. To reduce potenal radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that necessary for successful communicaon.
Conformément à la réglementaon d'Industrie Canada, le présent émeeur radio peut
fonconner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émeeur par Industrie Canada. Dans le but de réduire les risques de
brouillage radioélectrique à l'intenon des autres ulisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.)
ne dépasse pas l'intensité nécessaire à l'établissement d'une communicaon sasfaisante.
This equipment complies with IC RSS-102 radiaon exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with
minimum distance 20cm between the radiator & your body.
ce matériel est conforme aux limites de dose d'exposion aux rayonnements, CNR-102 énoncée dans un autre environnement.cee eqipment devrait être installé et
exploité avec distance minimale de 20 entre le radiateur et votre corps.