Max. Failed Aempts for Face Auth.
Set the maximum live face detecon failed aempts. The system will lock the user's face for 5
minutes if the live face detecon is failed for more than the congured aempts. The same
user cannot authencate via the fake face within 5 minutes. Within the 5 minutes, the user
can authencate via the real face twice connuously to unlock.
Lock Authencaon Failed Face
Aer enabling the Live Face Detecon funcon, the system will lock the user's face for 5
minutes if the live face
detecon is failed for more than the congured aempts. The same
user cannot authencate via the fake face within 5 minutes. Within the 5 minutes, the user
can
authencate via the real face twice connuously to unlock.
Applicaon Mode
You can select indoor or others applicaon modes according to actual environment.
4. Click OK.
5. Oponal: Click Copy to, and then select the card reader(s) to copy the parameters in the page to
the selected card reader(s).
Congure
Parameters for Alarm Output
Aer adding the access control device, if the device links to alarm outputs, you can congure the
parameters.
Before You Start
Add access control device to the client, and make sure the device supports alarm output.
Steps
1. Click Access Control → Advanced
Funcon → Device Parameter to enter access control
parameter conguraon page.
2. In the device list on the
le, click to expand the door, select an alarm input and you can edit
the alarm input's parameters on the right.
3. Set the alarm output parameters.
Name
Edit the card reader name as desired.
Alarm Output
Acve Time
How long the alarm output will last aer triggered.
4. Click OK.
5.
Oponal: Set the switch on the upper right corner to ON to trigger the alarm output.
10.7.2
Congure Device Parameters
Aer adding the access control device, you can set its parameters such as network parameters.