User's Manual

Table Of Contents
7.2.3 Set RS-485 Parameters
The face recognion terminal can connect external access controller, secure door control unit or
card reader via the RS-485 terminal.
Steps
1. Tap Comm.
(Communicaon Sengs) on the Home page to enter the Communicaon Sengs
page.
2. On the
Communicaon Sengs page, tap RS-485 to enter the RS-485 tab.
Figure 7-6 Set RS-485 Parameters
3. Select an peripheral type according to your actual needs.
Note
If you select Access Controller: If connect the device to a terminal via the RS-485 interface, set
the RS-485 address as 2. If you connect the device to a controller, set the RS-485 address
according to the door No.
4. Tap the back icon at the upper le corner and you should reboot the device if you change the
parameters.
7.2.4 Set Wiegand Parameters
You can set the Wiegand transmission direcon.
Steps
1. Tap Comm. (Communicaon Sengs) on the Home page to enter the Communicaon Sengs
page.
2. On the Communicaon Sengs page, tap Wiegand to enter the Wiegand tab.
DS-K1T343 Series Face Recognion Terminal User Manual
27