User's Manual

Table Of Contents
Passing Mode
Select the controller which will control the barrier status of the device.
If you select According to Lane Controller's DIP Sengs, the device will follow the lane
controller's DIP sengs to control the barrier. The sengs on the soware will be invalid.
If you select According to Main Controller's Sengs, the device will follow the sengs of
the
soware to control the barrier. The DIP sengs of the lane controller will be invalid.
Free Passing Authencaon
If you enable this funcon, when both entrance and exit's barrier mode is Remain Open, the
pedestrians should authencate each me passing through the lane. Or an alarm will be
triggered.
Opening/Closing Barrier Speed
Set the barrier's opening and closing speed. You can select from 1 to 10. The greater the
value, the faster the speed.
Note
The recommended value is 6.
Audible Prompt Duraon
Set how long the audio will last, which is played when an alarm is triggered .
Note
0 refers to the alarm audio will be played unl the alarm is ended.
Temperature Unit
Select the temperature unit that displayed in the device status.
4.
Click OK.
9.7.2
Congure Device Parameters
Aer adding the access control device, you can set its parameters such as network parameters.
Set Parameters for Face
Recognion Terminal
For face recognion terminal, you can set its parameters including face picture database, QR code
authencaon, etc.
Steps
Note
This funcon should be supported by the device.
1.
Enter the Access Control module.
DS-K1T673 Series Face Recognion Terminal User Manual
136