User's Manual

Table Of Contents
Figure 8-20 Black Body Sengs
2.
Enable black body correcon
funcon.
3.
Put a black body in front of the camera. Make sure there are no other objects between the
camera and the black body.
4.
Set the distance between the black body and the camera (straight line), the emissivity of the
black body, and the temperature unit.
Note
The black body's temperature is xed.
5.
Click Calibr
ate, and draw the black body's posion on the page. When + is displayed on the black
body on the screen, the black body is calibrated.
6.
Click Save.
Draw Temperature Measurement Area
Click Conguraon → T
emperature → Temperature Measurement Area .
Drag the yellow frame in the live video to adjust the measurement area. Only the temperature
within the area can be measured by the system.
Click Save to save the sengs.
Click
or to record videos or capture pictures.
8.6.25 Set Biometric Parameters
DS-K1T690 Series Face Recognion Terminal User Manual