User's Manual
Table Of Contents
- Legal Information
- Symbol Conventions
- Regulatory Information
- Safety Instruction
- Available Models
- Chapter 1 Overview
- Chapter 2 Appearance
- Chapter 3 Installation
- Chapter 4 Wiring
- Chapter 5 Activation
- Chapter 6 Quick Operation
- Chapter 7 Basic Operation
- Chapter 8 Operation via Web Browser
- 8.1 Login
- 8.2 Live View
- 8.3 Person Management
- 8.4 Search Event
- 8.5 Device Management
- 8.6 Configuration
- 8.6.1 Set Local Parameters
- 8.6.2 View Device Information
- 8.6.3 Set Time
- 8.6.4 Set DST
- 8.6.5 View Open Source Software License
- 8.6.6 Upgrade and Maintenance
- 8.6.7 Log Query
- 8.6.8 Security Mode Settings
- 8.6.9 Certificate Management
- 8.6.10 Change Administrator's Password
- 8.6.11 Online Users
- 8.6.12 View Device Arming/Disarming Information
- 8.6.13 Network Settings
- 8.6.14 Set Video and Audio Parameters
- 8.6.15 Customize Audio Content
- 8.6.16 Set Image Parameters
- 8.6.17 Set Supplement Light Brightness
- 8.6.18 Set Beauty Parameters
- 8.6.19 Set Fusion Parameters
- 8.6.20 Time and Attendance Settings
- 8.6.21 General Settings
- 8.6.22 Video Intercom Settings
- 8.6.23 Access Control Settings
- 8.6.24 Temperature Measurement Settings
- 8.6.25 Set Biometric Parameters
- 8.6.26 Set Meeting Plans
- 8.6.27 Set Notice Publication
- Chapter 9 Client Software Configuration
- 9.1 Configuration Flow of Client Software
- 9.2 Device Management
- 9.3 Group Management
- 9.4 Person Management
- 9.5 Configure Schedule and Template
- 9.6 Set Access Group to Assign Access Authorization to Persons
- 9.7 Configure Advanced Functions
- 9.8 Door/Elevator Control
- Appendix A. Tips for Scanning Fingerprint
- Appendix B. Tips When Collecting/Comparing Face Picture
- Appendix C. Tips for Installation Environment
- Appendix D. Dimension
- Appendix E. Communication Matrix and Device Command
Figure 7-11 Temperature Measurement Parameters
The a
vailable parameters descripons are as follows:
T
emp. Detecon
When enabling the funcon, the device will authencate the permissions and at the same me
take the temperature. When disabling the device, the device will authencate the permissions
only
.
Normal Temp.
Edit the threshold according to actual situaon. If the detected temperature is higher or lower
than the congured parameters, an alarm will be triggered. By default, the minimum value is
1 °C and the ma
ximum value is 45 °C.
Temperature Compensaon
If the measured temperature is higher/lower than the actual object's temperature, you can set
the compensaon temperature here. Available range: -99 to 99.
Note
You can select the unit as celsius degree or fahrenheit degree.
Door Not Open (Abnormal Temperature)
When enabling the funcon, the door will not open when the detected temperature is higher or
lower than the congured temperature threshold. By default, the funcon is enabled.
T
emp. Measurement Only
When enabling the funcon, the device will not authencate the permissions, but only take the
temperature. When disabling the funcon, the device will authencate the permissions and at
the same me take the temperature.
DS-K1T690 Series Face Recognion Terminal User Manual
68