Quick Start Guide

4
Configuration
Device Wiring
Attendance Configuration
3
2
Access Control System Configuration
User Management
1
Note: The external power supply and the access control terminal should use the same GND cable.
Manage User: In the New (New User) interface, enter the
new user ID No., the user name, the card No. Register the
fingerprint, set the password, select the department, set the
user permission, select schedule template, set the authenca-
on mode and set the duress card. Save the parameters to
confirm adding.
ACS System Configuration:
In the ACS Parameters Seng interface, configure the terminal authencaon mode, the sub reader authencaon
mode, the door magnec status, the lock acon me, the door-open meout alarm, and the maximum mes for
authencaon.
Holiday Group Configuration:
In New (New Holiday Group) interface, enter a new holiday group name. Select New ACS Holiday and enter the holiday
No., the holiday name, the holiday start me and the holiday end me. Save the parameters to confirm adding.
Week Plan Configuration:
In the Week Plan menu, select New (New Week Plan) to configure the week plan parameters, including the No., the
name, the week plan me and the corresponding periods. Save the parameters to confirm adding.
Schedule Template Configuration:
In the Schedule Template menu, select New (New Schedule Template) to configure the schedule template parameters,
including the template No., the template name, the week plan and the holiday group. Save the parameters to confirm
adding.
Configure the shi via the device. You are able to schedule shi
by department or by individual depending on the user property.
The working flows are as follows:
Scheduling Shift by Department: Add User (See Step 1) -
Edit Department - Configure Shi - Add Holiday - Configure Shi
Schedule (by Department).
Edit Department: Select a department to edit in the department list. Select “Editand edit the department name, shi type and shi name. Save the parameters to confirm eding.
Configure Shift
Normal Shi: In the Normal Shi interface, configure the aendance rule, the normal shi aendance. Save the parameters to confirm seng.
Man-Hour Shi: In the Man-Hour Shi interface, configure the man-hour shi parameters. Save the parameters to confirm seng.
Add Holiday
In the New (New Holiday) interface, enter the holiday No, the holiday name, the holiday start me and the holiday end me. Save the parameters to confirm adding.
Configure Shift Schedule
Schedule Shi by Department: Select a department to configure in the By Dept. (Schedule by Department) interface. Configure the shi, the start date, the end date and the holiday.
Save the parameters to confirm configuraon.
Schedule Shi by Individual: Select New Individual Shi in the By Indiv. (Schedule by Individual) interface. Select a person to schedule in the New Individual Shi interface. Configure
the shi, the schedule start date and the end date. Save the parameters to confirm eding.
User Management
ACS Configuraon
Aendance
Configuraon
External Device Wiring Overview (Without Secure Door Control Unit)
External Device Wiring Overview (With Secure Door Control Unit)
Secure Door Control Unit
Wiring Terminal
Note: The external power supply and the secure door control terminal should use the same GND cable.
Attendance Report
Plug the USB disk in the device. In Report interface of Aendance interface, select a table type to export. Press the OK key to export the aendance report to the USB disk.
The device will automacally check the USB disk memory. If there is no enough space for exporng, a prompt will be displayed. You are able to configure the record over threshold
prompt and record delete funcon in the System interface.
Record over Threshold Pop up Prompt (%): If the aendance record memory reaches the configured value, the system will pop up a prompt to remind you. If configure the
threshold to 99%, the system will pop up a prompt to remind you to delete the aendance data when the capacity reaches the threshold. The available value: 1 to 99.
Record Delete: When the funcon is enabled, the terminal will delete the first 3000 aendance records when the memory is full, in order to save the new aendance records. By
default, the funcon is enabled. See Secon 5.2 Aendance Record Delete Rule in the User Manual of Fingerprint Time Aendance Terminal.
5
Scheduling Shift by Individual: Add User (See Step 1) - Configure Shi - Add Holiday - Configure Shi Schedule (by Individual).
User Management, Access Control System Configuraon and
Aendance Configuraon are three main parts of the Access
Control Terminal.
Regulatory Information
This product and - if applicable - the supplied accessories too are marked with "CE"
and comply therefore with the applicable harmonized European standards listed
under the RE Direcve 2014/53/EU, the EMC Direcve 2014/30/EU, the RoHS
Direcve 2011/65/EU.
2012/19/EU (WEEE direcve): Products marked with this symbol cannot be
disposed of as unsorted municipal waste in the European Union. For proper
recycling, return this product to your local supplier upon the purchase of
equivalent new equipment, or dispose of it at designated collecon points. For
more informaon see: www.recyclethis.info
2006/66/EC (baery direcve): This product contains a baery that cannot be
disposed of as unsorted municipal waste in the European Union. See the product
documentaon for specific baery informaon. The baery is marked with this
symbol, which may include leering to indicate cadmium (Cd), lead (Pb), or
mercury (Hg). For proper recycling, return the baery to your supplier or to a
designated collecon point. For more informaon see: www.recyclethis.info
Industry Canada ICES-003 Compliance
This device meets the CAN ICES-3 (B)/NMB-3(B) standards requirements.
This device complies with Industry Canada licence-exempt RSS standard(s). Operaon is subject to the following two condions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operaon of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radioexempts de licence. L'exploitaon est autorisée aux deux
condions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'ulisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est suscepble d'en compromere le fonconnement.
Under Industry Canada regulaons, this radio transmier may only operate using an antenna of a type and maximum (or lesser) gain approved for the
transmier by Industry Canada. To reduce potenal radio interference to other users, the antenna type and its gain should be so chosen that the equivalent
isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communicaon.
Conformément à la réglementaon d'Industrie Canada, le présent émeeur radio peut
fonconner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émeeur par Industrie Canada. Dans le but de réduire les risques
de brouillage radioélectrique à l'intenon des autres ulisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée
équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communicaon sasfaisante.
This equipment should be installed and operated with a minimum distance 20cm between the radiator and your body.
Cet équipement doit être installé et ulisé à une distance minimale de 20 cm entre le radiateur et votre corps.
—Consult the dealer or an experienced radio/TV technician for
help.
This equipment should be installed and operated with a
minimum distance 20cm between the radiator and your body.
FCC Conditions
This device complies with part 15 of the FCC Rules. Operaon is
subject to the following two condions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operaon.
EU Conformity Statement
FCC Information
Please take aenon that changes or modificaon not expressly approved by the
party responsible for compliance could void the users authority to operate the
equipment.
FCC compliance: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protecon against harmful interference in a
residenal installaon. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instrucons,
may cause harmful interference to radio communicaons. However, there is no
guarantee that interference will not occur in a parcular installaon. If this
equipment does cause harmful interference to radio or television recepon, which
can be determined by turning the equipment off and on, the user is encouraged to
correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separaon between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Use only power supplies listed in the user instrucons:
Model Manufacturer Standard
DSA-12PFT-12FUK 120100
DSA-12PFT-12FAU 120100
DSA-12PFT-12FIN 120100
DSA-12PFT-12FUS 120100
DSA-12PFT-12 FBZ 120100
Dee Van Enterprise Co., Ltd.
BS
Dee Van Enterprise Co., Ltd.
Dee Van Enterprise Co., Ltd.
Dee Van Enterprise Co., Ltd.
Dee Van Enterprise Co., Ltd.
AS
NBR
IEC
IS
Exit Buon
Power Input
SENSOR
BUTTON
B1
B2
B3
B4
Green/Brown
Black
Green/Black
Black
Lock Output
NC
C1
C2
C3
COM
NC
White/Purple
White/Black
White/Red
Red
Black
Door Magnec
Exit Buon
NO
Power
Electric Dropbolt
Electric Strike
Sensor Input
Door Magnec
View License:
You can view the device License via the website: hp://opensource.hikvision.com/Home/List?id=46
Scan the QR code to get the user
manual for detailed informaon.
Note that mobile data charges may
apply if Wi-Fi is unavailable.