User's Manual

Table Of Contents
4. Click OK.
5. Oponal: Click Copy to, and then select the access control device(s) to copy the parameters in
the page to the selected device(s).
Congure Parameters for Door/Elevator
Aer adding the access control device, you can congure its access point (door or oor)
parameters.
Before You Start
Add access control device to the client.
Steps
1. Click Access Control → Advanced Funcon → Device Parameter .
2. Select an access control device on the le panel, and then click to show the doors or oors of
the selected device.
3. Select a door or oor to show its parameters on the right page.
4. Edit the door or oor parameters.
Note
The displa
yed parameters may vary for dierent access control devices.
Some of the following parameters are not listed in the Basic Informaon page, click More to
edit the parameters.
Name
E
dit the card reader name as desired.
Door Contact
You can set the door sensor as remaining closed or remaining open. Usually, it is remaining
closed.
Exit
Buon Type
You can set the exit buon as remaining closed or remaining open. Usually, it is remaining
open.
Door Locked Time
Aer swiping the normal card and relay acon, the mer for locking the door starts working.
Ext
ended Open Duraon
The door contact can be enabled with appropriate delay aer person with extended accesss
needs swipes her/his card.
Door Le Open Timeout Alarm
The alarm can be triggered if the door has not been closed in a congured me period. If it is
set as 0, no alarm will be triggered.
Lock Door when Door Closed
DS-K1T981 Series Access Control Terminal User Manual
128