Note
•
There are 6 module-connecng lines in the package: 190 mm × 4 and 400
mm × 2.
•
Take the 400 mm module-connecng line for this step.
•
The green-yellow line in the package is for grounding.
6.
Fix the mounng frame onto the wall with 8 expansion bolts.
Figure 3-47 Fix the Mounng Frame
7.
Pass the main unit connecng line across the thread hole to the top grid of the
le frame. Thread the module-connecng line (190 mm) across the thread hole
of the frame. The lines should be placed as shown below.
Figure 3-48 Placement of Lines
8.
Connect the cables.
Video Intercom Module Door
Staon User Manual