Operating Instruction SB 4-A22 (01)

Table Of Contents
*2145464*
2145464 English 7
Status Meaning
2 LEDs light up. Charge state: 25 % to 50 %
1 LED lights up. Charge state: 10 % to 25 %
1 LED flashes. Charge state: < 10 %
1 LED flashes, the power tool is not in working or-
der.
The battery has overheated or is completely dis-
charged.
4 LEDs flash, the power tool is not in working or-
der.
The power tool is overloaded or has overheated.
Battery charge state cannot be indicated while the control switch is pressed and for 5 seconds after
the control switch has been released. If the LEDs of the charge state indicator flash, follow the
instructions in the 'Troubleshooting' section.
3.6 Items supplied
Bandsaw, operating instructions.
Other system products approved for use with this product can be found at your local Hilti Store or at:
www.hilti.group
4 Technical data
4.1 Bandsaw
SB 4-A22
Rated voltage
21.6 V
Ambient temperature
1 140
(−17 60 ℃)
Weight including battery B22⁄8.0
9.5 lb
(4.3 kg)
No-load speed
548 ft/min
(167 m/min)
Max. cutting depth
2.50 in
(63.5 mm)
Dimensions, bandsaw blade (Length x width x thickness)
28.875 in x 0.5 in x 0.02 in
(733 mm x 12.7 mm x 0.5 mm)
or 28.875 in x 0.5 in x 0.01 in
(733 mm x 12.4 mm x 0.35 mm)
Operating temperature
1 140
(−17 60 ℃)
Storage temperature range (without battery)
−4 158
(−20 70 ℃)
4.2 Battery
Battery operating voltage
21.6 V
Ambient temperature for operation
1 140
(−17 60 ℃)
Storage temperature
−4 104
(−20 40 ℃)
Battery charging starting temperature
14 113
(−10 45 ℃)