Operating Instruction PMD 200 (01)

Table Of Contents
*2275630*
2275630 English 17
PMD 200
Bluetooth frequency
2,400 MHz
2,483.5 MHz
Degree of protection (IEC 60529) without battery
IP 54
Tripod mount (BSW)
5/8 in
System measuring accuracy under favorable conditions*
±3 mm
(±0.1 in)
System measuring accuracy under unfavorable conditions**
±5 mm
(±0.2 in)
Storage temperature
−20 70
(−4 158 ℉)
Ambient temperature for operation
−10 40
(14 104 ℉)
Rated voltage
10.8 V
Rated current
350 mA
Max. site elevation
2000 m / 6560 ft AMSL
Max. humidity
80 %
4.1 Tablet
The technical data below constitute the minimum requirements for running the PMD 200 application.
PMC 200
Operating system
Android 7.0
Bluetooth
BLE
Display resolution
1,920 x 1,200
4.2 Battery
Battery operating voltage
10.8 V
Ambient temperature for operation
−17 60
(1 140 ℉)
Storage temperature
−20 40
(−4 104 ℉)
Battery charging starting temperature
−10 45
(14 113 ℉)
5 Preparations at the workplace
Observe the safety instructions and warnings in this documentation and on the product.
5.1 Charging the battery
1. Before charging the battery, read the operating instructions for the charger.
2. Make sure that the contacts on the battery and the contacts on the charger are clean and dry.
3. Use an approved charger to charge the battery. page 15
5.2 Inserting the battery
WARNING
Risk of injury by short circuit or falling battery!
Before inserting the battery, make sure that the contacts on the battery and the contacts on the product
are free of foreign matter.
Make sure that the battery always engages correctly.
1. Charge the battery fully before using it for the first time.