Figure 4 — Installation of Hilti KB-TZ2 carbon steel in the soffit of concrete over metal deck floor and roof
assemblies – W deck
Figure 5 — Installation of Hilti KB-TZ2 carbon steel in the soffit of concrete over metal deck floor and roof
assemblies – B deck
h
min,deck
Max. 3"
Lower flute installation
Min. 12 " typ.
Upper flute
installation
Min.
5/8"
1
Min.
3-7/8"
Min.
3-7/8"
Min. 1"
Min. 20-gauge steel deck
Lower flute installation
Upper flute
installation
Min. 6 " typ.
Min.
5/8"
1
Min. 20-gauge
steel deck
h
min,deck
Max. 1-1/2"
Min.
3-1/2"
Min. 3/4"
Min. 1-3/4"
1 5/8” clearance between the bottom of the drilled hole and the concrete surface is only applicable for upper flute installations. Refer to Tables 30 and 31 for minimum concrete thicknesses for