Use and Care Manual

UD 30 applications Insert tool type
Drill bit sizes, 1st
gear
Drill bit sizes, 2nd
gear
Drilling in wood Twist drills
Forstner drill bits
Hole saws
Auger bits
Flat bits (not self
cutting)
Max. 25 mm
Max. 40 mm
Max. 50 mm
Max. 20 mm
Max. 30 mm
Max. 20 mm
Max. 25 mm
Max. 30 mm
Driving Drywall screws 6/60 mm
2.6 Items supplied as standard
1 Power tool with side handle
1 Depth gauge
1 Chuck key (with keyed chuck)
1 Operating instructions
1 Hilti cardboard box or toolbox
2.7 Using extension cords
Use only extension cords of a type approved for the application and with conductors of adequate cross section.
The power tool may otherwise loose performance and the extension cord may overheat. Check the extension
cord for damage at regular intervals. Replace damaged extension cords.
Recommended minimum conductor cross section and max. cable lengths for the UD 16:
Conductor cross section 1.5 mm² 2mm² 2.5 mm² 3.5 mm²
Mains voltage 100V 30 m 50 m
Mains voltage 110120 V 30 m 50 m
Mains voltage 220240 V 90 m 140 m
Recommended minimum conductor cross section and max. cable lengths for the UD 30:
Conductor cross section 1.5 mm² 2mm² 2.5 mm² 3.5 mm²
Mains voltage 100V 40 m 60 m
Mains voltage 110120 V 30 m 50 m
Mains voltage 220240 V 100 m 160 m
Do not use extension cords with 1.25 mm² conductor cross section.
2.8 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this
application.
2.9 Using a generator or transformer
This power tool may be powered by a generator or transformer when the following conditions are fulfilled:
The unit must provide a power output in watts of at least twice the value printed on the type identification
plate on the power tool. The operating voltage must remain within +5% and 15% of the rated voltage at all
times, frequency must be in the 50 60 Hz range and never above 65 Hz, and the unit must be equipped with
automatic voltage regulation and starting boost.
en