Malfunction Possible cause Action to be taken
No fastener is driven. Foreign object in the area of the
fastener guide
Remove foreign objects and
nails from the area around the
fastener guide. page 14
The fastening tool is too hot. Allow the fastening tool to cool
down.
Electronic fault. Remove the gas can and then
reinsert it. If the problem
persists, use a new gas can.
The fastening tool is hot and
doesn’t work even after a
break.
The fastener driving rate was well
above 1,200 fastenings per hour.
Allow the fastening tool to cool
down.
No fastener is driven (or
driven only intermittently).
Ambient conditions are outside the
permissible range.
Make sure that the permissible
ranges, in accordance with the
technical data, are observed.
The gas can temperature is outside
the permissible range.
Make sure that the permissible
ranges, in accordance with the
technical data, are observed.
Gas bubbles have formed in the
gas regulating system.
Remove the gas can and then
reinsert it.
The tool was not lifted completely
away from the surface after driving
a fastener.
Lift the fastening tool completely
away from the working surface
after driving a fastener.
A fastener cannot be
removed from the fastener
guide.
A fastener has jammed in the fas-
tener magazine.
Release the jammed fastener.
13 Disposal
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative
for further information.
Do not dispose of power tools, electronic equipment or batteries as household waste!
14 Manufacturer’s warranty
Please contact your local Hilti representative if you have questions about the warranty conditions.
Printed: 07.06.2018 | Doc-Nr: PUB / 5261664 / 000 / 02