VC 125-6 VC 125-9 English Printed: 07.03.
Printed: 07.03.
1 Information about the documentation 1.1 About this documentation • • • Read this documentation before initial operation or use. This is a prerequisite for safe, trouble-free handling and use of the product. Observe the safety instructions and warnings in this documentation and on the product. Always keep the operating instructions with the product and make sure that the operating instructions are with the product when it is given to other persons. 1.2 Explanation of symbols used 1.2.
1.4 Declaration of conformity We declare, on our sole responsibility, that the product described here complies with the applicable directives and standards. A copy of the declaration issued by the certification department can be found at the end of this documentation. The technical documentation is filed and stored here: Hilti Entwicklungsgesellschaft mbH | Tool Certification | Hiltistrasse 6 | 86916 Kaufering, Germany 2 Safety 2.
▶ ▶ ▶ ▶ ▶ faultless operation of the appliance, all parts must be fitted correctly and must meet the necessary requirements. Have the appliance serviced by a qualified repair person using only identical replacement parts. Always lead the supply cord, the extension cord and the suction hose away to the rear when working. Always unplug the supply cord from the power outlet when the appliance is not in use (during breaks), before cleaning and maintenance and before changing the filter or accessories.
▶ ▶ ▶ 4 Wear protective gloves when using the appliance to pick up hot materials at temperatures of up to 60°C (140°F). When working with mineral drilling slurry, wear protective clothing and avoid skin contact with the slurry (pH > 9: caustic). Avoid contact with alkaline or acidic liquids. If contact accidentally occurs, rinse with water. In the event of the liquid coming into contact with the eyes, rinse the eyes with plenty of water and consult a doctor. English Printed: 07.03.
3 Description 3.1 Product overview English Printed: 07.03.
@ ; = % & ( Filter cover Supply cord hook On/off button Top section Hose socket Waste material container ) + § / : ∙ Catch Filter cleaning button Grip Hose holder Accessory holder Catch for filter cover 3.2 Use of the product as directed The products described here are industrial vacuum cleaners designed for universal, commercial use. They can be used for wet or dry applications.
Suction hose connector (C-DN/C-ID) Vacuum (max.) Ambient temperature (max.) Protection class Protection class VC 125-6 VC 125-9 3.2 psi (220 mbar) 3.2 psi (220 mbar) 1.4 in (35 mm) 104 ℉ (40 ℃) I IPX4 1.4 in (35 mm) 104 ℉ (40 ℃) I IPX4 5 Before use 5.1 Operating the appliance for the first time 1. 2. 3. 4. 5. 6. Open the two catches. Lift the vacuum cleaner top section away from the waste material container. Remove the accessories and packaging from the waste material container.
Note Make sure that the vacuum cleaner cannot run away or fall down. 6.1 Picking up dry dust Note Before picking up dry dust, especially dust from mineral materials, always check to ensure that the correct dust bag is fitted in the container. The material picked up by the vacuum cleaner can then be disposed of cleanly and easily. CAUTION Risk of injury. Hazardous material that has been picked up may escape if a filter element is not used. ▶ Never use the appliance without a filter element.
7 Care, maintenance, transport and storage 7.1 Care and maintenance WARNING Danger of electric shock! Carrying out care and maintenance while the supply cord is connected to the power outlet presents a risk of serious injuries including burns. ▶ Always unplug the supply cord before carrying out all care and maintenance tasks. Care • Carefully remove stubborn dirt from the tool. • Clean the air vents carefully with a dry brush. • Use only a slightly damp cloth to clean the casing.
2. 3. 4. 5. 6. 7. 8. Open the filter cover catches. Open the filter cover. Carefully remove the filter element, gripping it at the areas provided in the holder. Clean the sealing surface with a cloth. Fit the new filter element. Close the filter cover by flipping the cover catch forward. Close the filter cover catch. 7.4 Checking the container level monitoring system 1. 2. 3. 4. Make sure that the vacuum cleaner cannot run away or fall down. Pull the plug out of the power outlet. Open the two catches.
8.1 Troubleshooting Trouble or fault The vacuum turbine doesn’t start. The vacuum turbine switches itself off. The vacuum turbine doesn’t start after cleaning the waste material container. Suction power drops. Possible cause No electric power. The electrodes are dirty. Action to be taken ▶ ▶ Check the power outlet and fuse. Clean the electrodes. The container is full. ▶ Empty the container. The automatic cut-out is active. ▶ ▶ ▶ The electrodes are dirty. Switch the appliance off. Wait 5 seconds.