SDS

No: QA-TR-81064
1 / 4
品保-作標-S031, 様式-8, 改訂 2016/12/01
Tohoku Murata Manufacturing Co., Ltd.
1-1 Shimosugishita, Takakura, Hiwada-machi, Koriyama-shi, Fukushima, 963-0531 Japan
Phone: +81-24-955-7770 / Fax: +81-24-955-7884
SAFETY DATA SHEET
1. Product and Company Identification
Product Information
Product Category : Lithium Ion Rechargeable Battery Cell
Model Name : US18650VTC5A
Nominal Capacity : 2600 mAh ( 9.4 Wh)
Rated Capacity : 2500 mAh ( 9.0 Wh)
Average Operating Voltage : 3.60 V
Company Identification
Supplier’s Name : Tohoku Murata Manufacturing Co., Ltd.
Supplier’s Address :
1-1 Shimosugishita, Takakura, Hiwada-machi, Koriyama-shi, Fukushima,
963-0531 Japan
Information Telephone :
+81-24-955-7770
Date Prepared : Jan. 01, 2018
Signature of Paper :
2. Hazard Identification
Class Name : Not applicable for regulated class
Hazard : It may cause heat generation or electrolyte leakage if battery terminals contact with other
metals. Electrolyte is flammable. In case of electrolyte leakage, move the battery from fire
immediately.
Toxicity : Vapor generated from burning batteries, may make eyes, skin and throat irritate.
3. Composition / Information on Ingredients
IMPORTANT NOTE:
The battery should not be opened or burned since the following ingredients contained within the battery that
could be harmful under some circumstance if exposed or misused.
The cell contains neither metallic lithium nor lithium alloy.
Common chemical name / General name CAS Number
Concentration/
Concentration range
Lithium Nickel Cobalt Oxides (active material)
113066-89-0
35%
Graphite
7782-42-5
16%
Ethylen Cabonate
623-53-0
2%
Dimetyle Cabonate
616-38-6
7%
Lithium hexafluorophosphate
21324-40-3
3%
Aluminium
7429-90-5
5%
Cupper
7440-50-8
18%
Iron
7439-89-6
14%
UN number : UN3480
Watt-hour rating : 9.4 Wh / 9.0 Wh (Nominal / Rated)
4. First Aid Measures
The product contains organic electrolyte. In case of electrolyte leakage from the battery, actions described below
are required.
Eye contact : Flush the eyes with plenty of clean water for at least 15 minutes immediately, without
rubbing, and call a doctor. If appropriate procedures are not taken, this may cause an eye
irritation.

Summary of content (4 pages)