If the intended volume was not fully dispensed because dispensing was aborted, the tool LED shows
red.
For instructions on how to complete an aborted dispensing operation, see the section headed:
Completion of aborted dispensing operation page 11.
After grouting each drillhole, always check that there is enough mortar in the drillhole.
Observe the grouting volume of mortar stated in the instructions for the foil pack.
6.3 Completion of aborted dispensing operation
If the dispensing operation was aborted prematurely by:
1. release of the trigger before the end of the dispensing operation
2. not enough mortar for the dispensing operation left in the foil pack/cartridge
3. battery discharged
the tool LED shows red.
You can complete an interrupted dispensing operation by double-clicking and holding down the trigger.
The green tool LED shows to indicate correct completion of the dispensing operation.
After changing foil pack/cartridge and discarding the initially dispensed volume of mortar by means
of the discard function, before double-clicking the trigger you must reset the dispensing wheel to the
dispensing volume originally desired.
This function is available for all positions on the dispensing mode selector switch, except the positions
for continuous dispensing and discard function.
After grouting each drillhole, always check that there is enough mortar in the drillhole.
Observe the grouting volume of mortar stated in the instructions for the foil pack/cartridge.
6.4 Removing the foil pack holder and foil pack 7
1.
Set the dispensing mode selector switch to .
2. Press the release button.
3. Pull the piston rod back as far as they will go.
4. Swivel the foil pack holder up.
5. Remove the foil pack.
6. Press the tab on the foil pack holder.
7. Press the foil pack holder down at the rear locating lug.
8. Pull the foil pack holder down from the front locating lug.
6.5 Removing the cartridge 8
1.
Set the dispensing mode selector switch to .
2. Press the release button.
3. Pull the piston rod back as far as they will go.
4. Swivel the cartridge upwards.
5. Press the cartridge down at the rear locating lug.
6. Pull the cartridge down from the front locating lug.
7 Care and maintenance
WARNING
Risk of injury with battery inserted !
Always remove the battery before carrying out care and maintenance tasks!
Care of the product
Carefully remove stubborn dirt from the tool.
Keep the tool LED clean at all times.
Carefully clean the ventilation slots, if present, with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
these can attack the plastic parts.