Product Technical Guide for CB-G EG Epoxy Grout

366
Hilti, Inc. (US) 1-800-879-8000 | www.us.hilti.com I en español 1-800-879-5000 I Hilti (Canada) Corp. 1-800-363-4458 I www.hilti.ca I Anchor Fastening Technical Guide 2011
Construction Chemicals
4.4.3 CB-G EG Epoxy Grout
Advantages
•Non-hazzardousandnon-corrosive
per DOT shipping classification
•Highearlyandultimatestrengths
•Highvibrationresistance
•Deeppour,lowshrinkage
•Self-leveling
•Highresistancetoavarietyof
chemicals
Trades and Facilities
•Civilprojects
•Concreteprofessionals
•Energyfacilities
•Generalcontractors/construction
managers
•Industrialplants
•Ornamentalsteelartisans
•Steelerectors
Purposes and Uses
•Groutingofmachineryandequipment
with high load requirements
•Precisionalignmentunderdynamic
load conditions
•Structuralgroutingofbaseplates,
columns, beams, crane rails, bridge
seats, dowels, etc.
•Chemicalprocessingfacilities
Hilti Epoxy Grout is a Buy-American
compliant,threecomponent,100%
solids, VOC and BGE free, non-corro-
sive, high performance epoxy grouting
system. This specially formulated grout
offers high strength providing excellent
resistance to impact and vibration. Us-
ing the most advanced amine technolo-
gy this grout meets today’s needs of an
effective and easy to use epoxy grout
designed to help protect people and
the environment.
4.4.3.1 Product Description
4.4.3.3 Installation Instructions
Read product instructions and MSDS before use
Preparation
The surfaces to be grouted must be
solid, clean and free from oil, grease,
and other contaminants that may act
as a bond breaker. Remove all loose
material and laitance. Concrete surfaces
must be dry, sound and roughened to
obtain proper bond. The grout and the
affected grouting area should be kept
between 50° F and 90° F (10° C and
32° C) and shaded from direct sunlight.
During cold weather it is important that
the grouted areas be kept warm (above
50°F or 10°C) until the grout has cured
completely. Store material at room
temperature for at least 24 hours before
use. Set time and strength development
are dependant on ambient temperature.
Hot temperatures will accelerate the
setting process of the grout where
cold temperatures will have a retarding
effect. Metal surfaces to come into
contact with the epoxy grout should be
sandblasted to a white metal finish and
wiped clean with a solvent before grout
is applied. Apply grout immediately
to prevent re-oxidizing or moisture
condensation.
4.4.3.2 Material Specifications /
Technical Data
Color: Concrete gray
Aspect Imperial Metric
Compressive strength, psi (MPa)
per ASTM D 695
8 hour 6,000 (41)
16 hour 12,000 (83)
1 day 12,500 (86)
3 days 14,000 (97)
7 days 15,000 (103)
Flexural strength, psi (MPa) per ASTM C 580 - 7 days 3,900 (27)
Tensile strength, psi (MPa) per ASTM C 307 - 7 days 2,100 (14)
Heat distortion temperature, °F (°C) per ASTM D 648 170 (77)
Working time at 72°F (22°C), minutes 45

Summary of content (2 pages)