ETA_19-0556_HSL-4_03-06-2021

Table Of Contents
European Technical Assessment ETA - 1 9 / 0 5 5 6
English translation prepared by CSTB
Page 24 of 29 | 03/06/2021
Hilti heavy duty anchor HSL4
Annex C10
Table C10: Characteristic values of resistance under shear load in case of seismic
category C2 - HSL4, HSL4-G, HSL4-B, HSL4-SK
1)
In absence of other national regulations
2)
The influence of the thickness of fixture to the characteristic resistance for shear loads, steel failure without lever arm
is taken into account
Size
M10
M12
M16
M20
M24
Setting position
Effective
anchorage depth
h
ef
[mm]
70
90
110
80
105
130
100
125
150
125
155
185
150
180
210
Steel failure without lever arm
Partial safety factor
Ms,seis
1)
[-]
1,25
HSL4, HSL4-B
Characteristic
resistance
V
Rk,s,seis
[kN]
25,4
30,5
61,8
78,1
87.9
HSL4-SK
Characteristic
resistance
t
fix
2)
[mm]
>=11
>=13
-
V
Rk,s,seis
[kN]
25,4
30,5
HSL4-G
Characteristic
resistance
V
Rk,s,seis
[kN]
22.5
22,5
44,6
50,2
77.7
Concrete pryout failure
Installation safety
factor
inst
[-]
1,0
Concrete edge failure
Installation safety
factor
inst
[-]
1,0
Performances
Characteristic resistance under seismic actions, seismic category C2