Hilti heavy duty anchor HSL4
Annex C12
Table C14: Chracteristic tension resistance under fire exposure for Hilti metal
expansion anchor HSL4, HSL4-G, HSL4-B, HSL4-SK in cracked and
uncracked concrete
1)
Pull-out failure is not decisive for design.
2)
In absence of other national regulations the partial safety factor for resistance under fire exposure γM,fi = 1,0 is
recommended.
Size
M8
M10
M12
M16
M20
M24
Setting position
Effective
anchorage depth
h
ef
[mm]
60
80
100
70
90
110
80
105
130
100
125
150
125
155
185
150
180
210
Steel failure
HSL4, HSL4-G, HSL4-B, HSL4-SK
Characteristic
resistance
R30
N
Rk,s,fi
[kN]
2,7
4,2
6,0
11,1
17,4
25,0
R60
N
Rk,s,fi
[kN]
2,1
3,5
5,3
9,9
15,4
22,2
R90
N
Rk,s,fi
[kN]
1,5
2,8
4,6
8,6
13,4
19,3
R120
N
Rk,s,fi
[kN]
1,2
2,4
4,3
8,0
12,4
17,9
Pullout failure
HSL4, HSL4-G, HSL4-B, HSL4-SK
Characteristic
resistance
≥C20/25
R30
N
Rk,p,fi
[kN]
3,0
4,0
-
1)
6,0
-
1)
9,0
-
1)
12,5
-
1)
16,3
R60
N
Rk,p,fi
[kN]
R90
N
Rk,p,fi
[kN]
R120
N
Rk,p,fi
[kN]
2,4
3,2
-
1)
4,8
-
1)
7,2
-
1)
10,0
-
1)
13,0
Performances