ETA_19-0556_HSL-4_03-06-2021
Table Of Contents
European Technical Assessment ETA - 1 9 / 0 5 5 6
English translation prepared by CSTB
Page 27 of 29 | 03/06/2021
Hilti heavy duty anchor HSL4
Annex C13
Table C14: Continued
In absence of other national regulations the partial safety factor for resistance under fire exposure γM,fi = 1,0 is
recommended.
Size
M8
M10
M12
Setting position
Effective
anchorage depth
h
ef
[mm]
60
80
100
70
90
110
80
105
130
Concrete cone failure and splitting failure
HSL4, HSL4-G, HSL4-B, HSL4-SK
Characteristic
resistance
≥C20/25
R30
N
Rk,c,fi
[kN]
5,0
10,3
18,0
7,4
13,8
22,8
10,3
20,3
34,7
R60
N
Rk,c,fi
[kN]
R90
N
Rk,c,fi
[kN]
R120
N
Rk,c,fi
[kN]
4,0
8,2
14,4
5,9
11,1
18,3
8,2
16,3
27,7
Spacing
s
cr,N
[mm]
240
320
400
280
360
440
320
420
520
Edge distance
c
cr,N
[mm]
120
160
200
140
180
220
160
210
260
Size
M16
M20
M24
Setting position
Effective
anchorage depth
h
ef
[mm]
100
125
150
125
155
185
150
180
210
Concrete cone failure and splitting failure
HSL4, HSL4-G, HSL4-B, HSL4-SK
Characteristic
resistance
≥C20/25
R30
N
Rk,c,fi
[kN]
18,0
31,4
49,6
31,4
53,8
83,8
49,6
78,2
115,0
R60
N
Rk,c,fi
[kN]
R90
N
Rk,c,fi
[kN]
R120
N
Rk,c,fi
[kN]
14,4
25,2
39,7
25,2
43,1
67,0
39,7
62,6
92,0
Spacing
s
cr,N
[mm]
400
500
600
500
620
740
600
720
840
Edge distance
c
cr,N
[mm]
200
250
300
250
310
370
300
360
420
Performances
Characteristic resistance of tension load resistance under fire resistance