5.12 The Hilti HIT-HY 200 V3 Adhesive Anchor System may
be installed in base materials having interior
temperatures between 14°F (-10°C) and 104°F (40°C)
for threaded rods, rebars, and Hilti HIS-(R)N inserts or
between 41°F (5°C) and 104°F (40°C) for HIT-Z(-R)
anchor rods at the time of installation. Installation of
HIT-HY 200 V3 adhesive in base materials having
temperatures beyond this range is outside the scope of
this report.
5.13 When anchors are located where the base-material
temperature may exceed 70°F (21°C), allowable
tension and shear loads indicated in this report must
be adjusted for in-service temperatures in accordance
with Figure 1. The use of HIT-HY 200 V3 adhesive in
base materials having interior temperatures exceeding
180°F (82°C) during their service life is outside the
scope of this report.
5.14 Steel anchoring materials in contact with preservative-
treated wood or fire-retardant-treated wood must be
stainless steel or hot-dipped galvanized in accordance
with ASTM A153 Class C or D.
5.15 Special inspection in accordance with Section 4.3 of
this report must be provided for all anchor installations.
5.16 The Hilti HIT-HY 200 V3 Adhesive Anchor Systems
must be installed in holes created using a carbide-
tipped masonry drill bit manufactured within the range
of the maximum and minimum dimensions of ANSI
B212.15-1994.
5.17 Hilti HIT-HY 200-A V3 and Hilti HIT-HY 200-R V3
adhesives are manufactured by Hilti GmbH, Kaufering,
Germany, with quality control inspections by ICC-ES.
5.18 The Hilti HIT-Z and HIT-Z(-R) rods are manufactured
by Hilti AG, Schaan, Liechtenstein, with quality control
inspections by ICC-ES.
5.19 The Hilti HIS-N and HIS-RN inserts are manufactured
by Hilti (China) Ltd., Guangdong, China, with quality
control inspections by ICC-ES.
6.0 EVIDENCE SUBMITTED
6.1 Data in accordance with the ICC-ES Acceptance
Criteria for Adhesive Anchors in Masonry Elements
(AC58), dated March 2018, including tests on the
effects of edge distance on tension performance (Test
Series 4 and 5); the effects of spacing on tension
performance (Test Series 8 and 9), the effects of
spacing on shear performance; the effects of edge
distance on shear performance (Test Series 13 and 14)
for installations in grout-filled CMU; and suitability tests
(Test Series 17 through 21) for installations in grout-
filled CMU walls.
6.2 A quality-control manual.
7.0 IDENTIFICATION
7.1 The Hilti HIT-HY 200-A V3 and Hilti HIT-HY 200-R V3
adhesive is identified by packaging labeled with the
manufacturer’s name (Hilti Corp.) and address,
product name, lot number, expiration date, and
evaluation report number (ICC-ES ESR-4878).
7.2 The Hilti HIT-Z and HIT-Z(-R) rods are identified by
packaging labeled with the manufacturer's name
(Hilti Corp.) and address, anchor name, and evaluation
report number (ICC-ES ESR-4878).
7.3 The Hilti HIS-N and HIS-RN inserts are identified by
packaging labeled with the manufacturer's name
(Hilti Corp.) and address, anchor name and size, and
evaluation report number (ICC-ES ESR-4878).
7.4 Threaded rods, reinforcing bars, nuts, washers, bolts,
cap screws, and deformed reinforcing bars are
standard elements and must conform to applicable
national or international specifications.
7.5 The report holder’s contact information is the following:
HILTI, INC.
7250 DALLAS PARKWAY, SUITE 1000
PLANO, TEXAS 75024
(918) 872-8000
www.hilti.com