FIGURE 1—PRE-SETTING ANCHOR HDA-P AND HDA-PR (PRE-POSITIONING)
FIGURE 2—THROUGH-FASTENING ANCHOR HDA-T AND HDA-TR (POST-POSITIONING)
TABLE 1—ANCHOR DIMENSIONAL CHARACTERISTICS (mm)
Anchor type
t
fix
1
[mm]
min-max
l
B
[mm]
Length
code
letter
l
S
[mm]
l
k
[mm]
SW
d
S1
[mm]
d
S2
[mm]
d
S3
[mm]
d
C
[mm]
d
B
[mm]
HDA-P(R) M10x100/20 0-20 150 I 100 - 17 19 16.8 18.5 19.5 10
HDA-T(R) M10x100/20 10-20 150 I 120 17 17 19 16.8 18.5 19.5 10
HDA-P(R) M12x125/30 0-30 190 L 125 - 19 21 18.8 20.5 21.4 12
HDA-P(R) M12x125/50 0-50 210 N 125 - 19 21 18.8 20.5 21.4 12
HDA-T(R) M12x125/30 10-30 190 L 155 27 19 21 18.8 20.5 21.4 12
HDA-T(R) M12x125/50 10-50 210 N 175 47 19 21 18.8 20.5 21.4 12
HDA-P(R) M16x190/40 0-40 275 R 190 - 24 29 26 29 29 16
HDA-P(R) M16x190/60 0-60 295 S 190 - 24 29 26 29 29 16
HDA-T(R) M16x190/40 15-40 275 R 230 35.5 24 29 26 29 29 16
HDA-T(R) M16x190/60 15-60 295 S 250 35.5 24 29 26 29 29 16
HDA-P M20x250/50 0- 50 360 V 250 - 30 35 32 35 36 20
HDA-P M20x250/100 0-100 410 X 250 - 30 35 32 35 36 20
HDA-TM20x250/50 20-50 360 V 300 45 30 35 32 35 36 20
HDA-T M20x250/100 50-100 410 X 350 95 30 35 32 35 36 20
For in-lb units: 1 mm = 0.03937 inches
1
first value: t
fix,min
minimum fixture thickness for pure tension load (shear load see Table 6), second value: t
fix,max