Operating Instruction DX 351 (01)

Cartridge strip melts
Cartridge cannot be fired
25
en
Cartridge strip cannot be
removed
10. Troubleshooting
Cartridge not transported
Fault
Cause
Damaged cartridge strip
Carbon build up
Tool damaged
Tool overheated because of high
setting rate
Tool damaged
WARNING
Never attempt to pry a cartridge
from the magazine strip or tool.
Bad cartridge
Carbon build-up
WARNING
Never attempt to pry a cartridge
from the magazine strip or the tool.
Possible remedies
Change cartridge strip
Clean the cartridge strip guide-
way (see 8.6)
If the problem persists:
Contact Hilti Repair Centre
Let the tool cool down and then
carefully try to remove the
cartridge strip
If not possible:
Contact Hilti Repair Centre
Manually advance the cartridge
strip one cartridge
If the problem occurs more
often:
Clean the tool (see 8.1–8.8)
If the problem persists:
Contact Hilti Repair Centre
Tool is compressed too long
while fastening.
Fastening frequency is too high
Compress the tool only while
fastening.
Remove the cartridge strip
Disassemble the tool (see
7.1–7.3)
for fast cooling and to avoid
possible damage
Do not exceed the recommended
fastener driving rate
If the tool cannot be disassembled:
Contact Hilti Repair Centre