Operating Instruction DX 351 (01)

Varying depths of penetration
26
en
Cartridge falls out of the
cartridge strip
The operator notices:
– increased contact pressure
– increased trigger force
– power regulation stiff to adjust
– cartridge strip is difficult to
remove
Fastening frequency is too high
WARNING
Never attempt to pry a cartridge
from the magazine strip or tool.
Carbon build-up
Immediately discontinue using
the tool and let it cool down
Remove cartridge strip
Let the tool cool down
Clean the tool and remove loose
cartridge
If it is impossible to disassemble
the tool:
Contact Hilti Repair Centre
Clean the tool
(see 8.1–8.8)
Check that the correct cartridges
are used (see 1.2) and that they
are in faultless condition.
The tool is dirty (carbon build-
up)
Clean the tool
(see 8.1–8.8)
Check piston, replace if neces-
sary
Fault
Cause Possible remedies
Trigger cannot be pulled
Tool not fully compressed
Safety mechanism activated
because:
– Magazine not loaded
– Plastic debris inside the
magazine
– Incorrect piston position
– Nail incorrectly positioned in
magazine
Release the tool and fully com-
press it again
Load fastener strip
Open magazine, remove fastener
strip and plastic debris
If problem persists:
Clean the tool (see 8.1–8.8)
Check to ensure that the tool is
assembled correctly