Supplement for Hilti Anchors For Attachments to Hollow Core Concrete Panels

Hilti Anchors for attachments to Hollow Core Concrete Panels
3
August 2019
DESIGN INFORMATION
Table 2 — Hilti KWIK HUS-EZ (KH-EZ) and KWIK HUS-EZ P (KH-EZ P) loads in hollow core concrete panels
1,2
Anchor Diameter
(inches)
Min. effective
embedment h
ef
(inches)
Allowable loads, lb (kN)
3
Ultimate load lb (kN)
Tension Shear Tension Shear
1/4
1-1/8 400 (1.8) 610 (2.7) 1600 ( 7.1) 2440 (10.9)
1-3/8 525 (2.3) 770 (3.4) 2100 (9.3) 3080 (13.7)
3/8
1-1/8 435 (1.9) 890 (4.0) 1740 ( 7.7 ) 3560 (15.8)
1-3/8 590 (2.6) 1405 (6.3) 2360 (10.5) 5620 (25.0)
1 The admissable anchor location must be established to prevent damage to the prestressed cable during the drilling process. Verify the location and height of the cable with the hollow core
plank supplier to confirm admissable anchor location.
2 Minimum compressive strength of prestressed concrete is 7,000 psi. Published results represent the average results conducted in local base materials. Due to variations in materials and
dimensional configurations, on-site testing is required to determine the actual performance
3 Allowable loads calculated with a factor of safety of 4.
ORDERING INFORMATION
Description Hole Diameter
Total Length
without
Anchor Head
Qty (pcs) / Box
KH-EZ 1/4"x1-7/8"
1/4" 1-7/ 8" 100
KH-EZ 1/4"x2-5/8"
1/4" 2-5/8" 100
KH-EZ 1/4"x3"
1/4" 3" 100
KH-EZ 1/4"x3-1/2"
1/4" 3-1/2" 100
KH-EZ 1/4"x4"
1/4" 4" 100
KH-EZ P 1/4"x1-7/8”
1/4" 1-7/ 8" 100
KH-EZ P 1/4"x2-5/8"
1/4" 2-5/8" 100
KH-EZ 3/8"x1-7/8"
3/8" 1-7/ 8" 50
KH-EZ 3/8"x2-1/8"
3/8" 2-1/8" 50
KH-EZ 3/8"x3"
3/8" 3" 50
KH-EZ 3/8"x3-1/2"
3/8" 3-1/2" 50
KH-EZ 3/8"x4"
3/8" 4" 50
KH-EZ 3/8"x5"
3/8" 5" 30
INSTALLATION PAR AMETERS
Table 1 — KWIK HUS-EZ and KWIK HUS-EZ P
specifications
Setting information Symbol Units
Nominal anchor diameter
1/4 3/8
Head style
Hex
head
Pan
head
Hex
head
Nominal bit diameter d
bit
in. 1/4 3/8
Minimum base material thickness h
min
in. 1-1/8
Minimum Fixture hole diameter d
h
in. 3/8 1/2
Minimum anchor spacing s
min
in. 4-1/8
Minimum edge distance c
min
in. 3-3/4
Installation torque
1
T
inst
ft-lb 18 19
(Nm) (24) (26)
Maximum impact wrench torque
rating
2
T
impact, max
ft-lb 114
(Nm) (155)
Wrench or Torx bit size in. 7/16 T30 9/16
1 T
inst
is the maximum installation torque that may be applied with a torque wrench.
2 Because of variability in measurement procedures, the published torque of an impact tool
may not correlate properly with the above setting torques.
Over torquing can damage the anchor and/or reduce its holding capacity.
Figure 1 — Installation of Hilti KWIK HUS-EZ
(KH-EZ) and KWIK HUS-EZ P (KH-EZ P)
in hollow core concrete panels