HDI-P TZ FLUSH ANCHORS
PRODUCT DESCRIPTION
HDI-P TZ Flush anchors
Anchor System Features and Benets
Carbon steel
HDI-P TZ
Flush anchor anchor with optimized length
for reliable fastenings in post-tensioned cable
concrete slabs
Suitable for uncracked and cracked concrete
including seismic areas
Productive installation with HDI-P TZ automatic
setting tool with hammer drill
Used with Hilti Dust Removal System (DRS) for
compliance with Table 1 of OSHA 1926.1153
regulations for silica dust exposure
Shallow drilling for fast installations
Easy installation with Auto Setting Tool
Lip provides flush installation, consistent anchor
depth, and easy rod alignment
Auto Setting Tool includes stop drill bit and
setting tool, no tool change necessary
Auto-setting tool
HDI-P TZ
Hand-setting tool
HDI-P TZ
INSTALLATION PAR AMETERS
Table 7 — HDI-P TZ Specifications
Setting information Symbol Unit
Nominal
anchor size /
internal
thread dia.
(in)
3/8
Nominal bit diameter
d
bit
in. 9/16
Threaded rod diameter d
rod
in. 3/8
Minimum base material thickness h
min
in. 1-3/8
Anchor length
in.
(mm)
3/4
(19.1)
Hole depth in base material h
0
in.
(mm)
3/4
(19)
Minimum anchor spacing
s
min
in. 8
Minimum edge distance c
min
in. 8
1 The Admissible Anchor Location must be established to prevent damage to the
prestressed cable during the drilling process. Verify the location and height of the cable
with the hollow core plank supplier to confirm Admissible Anchor Location.
2 Minimum compressive strength of hollow core panels is 7,000 psi at the time of installation.
The minimum thickness h
min
is 1-3/8 inches.
Figure 4 — Installation HDI-P TZ in hollow core
concrete panels