ICC ESR-1546 for HDA Undercut Anchors

ESR-1546
|
Most Widely Accepted and Trusted Page 6 of 16
Pre-setting anchor HDA-P and HDA-PR (Prepositioning)
Through-fastening anchor HDA-T and HDA-TR (Postpositioning)
FIGURE 3—HDA DIMENSIONS
TABLE 2—CHARACTERISTIC VALUES OF ANCHORS AND INSTALLATION
1,2,3
HDA M10 to M20 and
HDA-R M10 to M16
M10 M12 M16 M20
P T P T P T P T
Nominal drill bit
diameter
1
d
bit
mm 20 20 22 22 30 30 37 37
Minimum hole
depth
1,2
h
hole
mm 107 107 133 133 203 203 266 266
(in.) (4.21) (4.21) (5.30) (5.30) (7.99) (7.99) (10.47) (10.47)
Maximum clearance
hole diameter in
fastened part
d
h
mm 12 21 14 23 18 32 22 40
(in.) (0.47) (0.83) (0.55) (0.91) (0.71) (1.26) (0.87) (1.57)
Min. thickness of
fastened part
t
min
mm 0 10 0 10 0 15 0 20
(in.) 0 (0.39) 0 (0.39) 0 (0.59) 0 (0.79)
Sleeve recess
3
h
s
mm 2 ≤ h
s
≤ 6 2 ≤ h
s
≤ 7 2 ≤ h
s
≤ 8 2 ≤ h
s
≤ 8
(in.) (0.08 ≤ h
s
≤ 0.24) (0.08 ≤ h
s
≤ 0.28) (0.08 ≤ h
s
≤ 0.31) (0.08 ≤ h
s
≤ 0.31)
Installation torque T
inst
Nm 50 50 80 80 120 120 300 300
(ft-lb) (37) (37) (59) (59) (89) (89) (221) (221)
For in-lb units: 1mm = 0.03937 inches, 1 Nm = 0.7376 ft-lb
1
Use required stop drill bits only. See Table 4b and 4c
2
Actual hole depth for HDA-T is provided by minimum hole depth + (t
fix max
- t
fix
) where t
fix max
is provided in Table 3B and t
fix
is the thickness of the part(s)
being fastened.
3
Sleeve recess after setting of the anchor:
a) Pre-setting anchor HDA-P(R): distance from surface of the concrete member to top edge of the anchor sleeve (see Figure 1)
b) Through-fastening anchor HDA-T(R): distance from top edge of the fixture to top edge of the anchor sleeve (see Figure 2)
TABLE 3A—MINIMUM THICKNESS OF CONCRETE MEMBER, HDA-P AND HDA-PR
Anchor type
HDA-P M10
HDA-PR M10
HDA-P M12
HDA-PR M12
HDA-P M16
HDA-PR M16
HDA-P M20
Minimum thickness of
concrete member
h
min
mm 180 200 270
1
350
(in.) (7.1) (7.9) (10.6) (13.8)
For in units: 1mm = 0.03937 inches
1
With TE 70 h
min
≥ 300mm (11.8 in) for HDA-P(PR) M16.
TABLE 3B—MINIMUM THICKNESS OF CONCRETE MEMBER, HDA-T AND HDA-TR
1
Anchor type
HDA-T M10
HDA-TR M10
HDA-T M12
HDA-TR M12
HDA-T M16
HDA-TR M16
HDA-T M20
Maximum fastenable
thickness
t
fix,max
mm 20 30 50 40 60 50 100
Minimum thickness of
concrete member
1
h
min
mm 200-t
fix
230-t
fix
250-t
fix
310-t
fix
2
330-t
fix
2
400-t
fix
450-t
fix
(in.) (7.9- t
fix
) (9.1- t
fix
) (9.8- t
fix
) (12.2- t
fix
) (13.0- t
fix
) (15.7- t
fix
) (17.7- t
fix
)
For in units: 1mm = 0.03937 inches
1
h
min
is dependent on the actual fixture thickness t
fix
(use of a stop drill bit) e.g. HDA-T M12*125/50 : t
fix
= 20mm h
min
= 250-20 = 230mm
t
fix
= 50mm h
min
= 250-50 = 200mm.
2
With TE 70 h
min
= 340mm - t
fix
for t
fix,max
= 40mm and h
min
= 360mm - t
fix
for t
fix,max
= 60mm when using HDA-T(TR) M16.